Troubleshooting
8-104
Chapter 8: Service & maintenance
98-133966-G1
8.8.3.1
How to understand events shown in the
Diagnostic report
Below is an example of a system which has failed to power up.
The SAILOR 900 VSAT will after ended POST go into safe mode,
identified by the "ADU_IF: Error type not eligible for ADU auto
recovery (14:20)".
Once in
safe mode
the 48 VDC to the antenna will drop to 20VDC,
leaving all axes without power. (All status LED on antenna modules will
go RED.) To run a new POST the system must be rebooted.
The POST will hold the outcome of the power up self-test. ANY FAILED
POST test will cause the system to go into
safe mode
.
In the below POST the 0x00a023 Ele axis calibration has failed. That
will cause the 0x00a025 Antenna calibration to fail as well.
The events hold and show all events that have been detected during the
system lifetime.
Severity levels: (sev)
•
Error
means system = STOP
•
Warn
means system = RUN. BUT needs attention
States: (stat)
•
Set
means that the event is Active
•
Clr
means that the event has been cleared and is no longer active.
•
One
means that the system has detected an event but been able to
recover from it.
In the example below the following events are active = SET
SAILOR900TM.book Page 104 Monday, September 16, 2013 11:01 AM
Summary of Contents for Sailor 900 VSAT
Page 2: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 2 15 04 2013 15 54 39 ...
Page 28: ...List of tables xxvi 98 133966 G1 SAILOR900TM book Page xxvi Monday September 16 2013 11 01 AM ...
Page 257: ...Appendices SAILOR900TM book Page 1 Monday September 16 2013 11 01 AM ...
Page 258: ...SAILOR900TM book Page 2 Monday September 16 2013 11 01 AM ...
Page 355: ...98 138976 A Cover_SAILOR 900 VSAT System_407090B indd 3 15 04 2013 15 54 40 ...