23
Category:
II
2H3P.
(20, 37)
Flue Type:
A
1.
NOTE:
(*) Measure burner operating pressure at manifold test point with two burners operating at 'High Flame'
setting.
NAT, & LPG - Operating pressure is ex-factory set and is not to be adjusted, apart from when converting
between gases, if required.
Refer to the information in this section for further details.
Open Burner
Burner Injector
Ø 1.90mm
Ø 1.20mm
Low Fire Setting
¾ turn open c.c.w.
¼ turn open c.c.w.
Burner Aeration Setting
16mm open
16mm open
Griddle
Burner Injector
Ø 2.00mm
Ø 1.25mm
Low Fire Setting
5
/
8
turn open c.c.w.
3
/
8
turn open c.c.w.
Burner Aeration Setting
Fully open
Fully open
Pilot Injector
0.35
0.23
Oven
CR6
Model
Burner Injector
Ø 2.40mm
Ø 1.40mm
Low Fire Screw
Ø 1.00mm
Ø 0.60mm
Burner Aeration Setting
Fully open
10mm open
Pilot Injector
0.35
0.23
CR9
Model
Burner Injector
Ø 2.50mm
Ø 1.50mm
Low Fire Screw
Ø 1.50mm
Ø 0.90mm
Burner Aeration Setting
Fully open
Fully open
Pilot Injector
0.35
0.23
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure (*)
10 mbar
28 mbar
Gas Regulator Cap Screw
Summary of Contents for CR6 Series
Page 28: ......