A
Appendix A: Gas Type Conversion
©
Moffat Ltd, September 2008
27
Revision 1
Cobra Series CT6 Gas Griddle Toaster
Gas Regulator
- NAT Gas / LPG / Butane Only.
NOTE:
The regulator supplied is convertible
between Natural Gas and LP Gas, but it’s
outlet pressure is fixed ex-factory and is
NOT to be adjusted.
1. Ensure that the gas supply is turned 'Off' at the
mains.
2. Unscrew the hexagonal cap (23mm A/F) from
the regulator.
3. Un-clip the plastic pin from the cap, reverse the
pin and re-fit it back to the cap the correct way
for the gas type to be used.
(Either ‘LP’ or
‘NAT’ should be visible on the flank of the
pin once re-fitted to the cap)
.
4. Screw the cap back into the regulator hand
tight only.
- Town Gas Only.
1. Unscrew and remove the slotted cap from the
regulator.
2. Turn on the gas supply and the appliance.
3. Adjust the pressure adjusting nut to achieve the
correct burner operating pressure.
NOTE:
The operating pressure to be measured at
the manifold test point and with both
burners operating at the 'High Flame'
setting.
4. Turn 'Off' the mains gas supply and bleed the
gas out of the appliance gas lines.
5. Turn 'On' the gas supply and the appliance.
6. Verify the operating pressure remains correct
(Re-adjust the regulator if required).
7. Screw the cap nut back onto the regulator.
NOTE
, Pin rotated
for Natural Gas
NOTE
, Pin rotated
for LPG
Pressure Adjusting
Screw
Cap Nut
Figure A.5
Figure A.6