This guide is for recipients of the Cochlear

Nucleus

®

 Hybrid L24 Cochlear Implant. It 

providesinformation about using an acoustic
component with your sound procesor for
Hybrid Hearing. You can also choose a 
Cochlear Nucleus CR210 Remote Control or 
CR230 Remote Assistant to control 
your processor. For more about remotes, 
please consult your remote user guide. 

People with certain types of hearing loss can wear the processor in 
Hybrid mode by adding an acoustic component. The acoustic component 
sends amplified acoustic sound into the ear canal. 

A number of tools and accessories are supplied with your sound processor. 

NOTE

Please refer to the booklet Important 
Information: Warnings, Precautions and 
Electromagnetic Compatibility 
for important 
information that applies to cochlear 
implant systems.

Summary of Contents for Nucleus CP910

Page 1: ...Nucleus CP910 and CP920 Sound Processor Hybrid Hearing Supplement Patient Information FDA approved for use with the Hybrid L24 CI24REH Implant...

Page 2: ...Nucleus Hybrid Implant Compact rechargeable battery module CP920 Sound Processor with Acoustic Component with Compact Rechargeable Battery Module Microphones and microphone protectors Coil Indicator l...

Page 3: ...u can also choose a Cochlear Nucleus CR210 Remote Control or CR230 Remote Assistant to control your processor For more about remotes please consult your remote user guide People with certain types of...

Page 4: ...4 Wear 4...

Page 5: ...battery module a coil and coil cable a closed accessory socket no acoustic component Your processor is protected against failure from splashing water or access of foreign objects 1 0 mm in diameter o...

Page 6: ...the coil in one hand and place the processor on your ear with the other 1 Place the coil on your head 2 Place your dome or earmould in your ear as instructed by your clinician 3 When removing your coi...

Page 7: ...component Wear your processor without the acoustic component by replacing it with a standard earhook Talk to your clinician before replacing Locate the opening under the earhook 2 Remove the battery m...

Page 8: ...click it off the sound processor 5 Insert a Cochlear EAC200 Series Screwdriver into the hole Carefully push and twist the screwdriver until the speaker unit cable disconnects 3 CAUTION Use only the E...

Page 9: ...9 COCHLEAR NUCLEUS 6 HYBRID HEARING SUPPLEMENT Click the standard earhook into place 7 Insert a new processing unit plug into the speaker unit cable socket Make sure the plug goes all the way in 6...

Page 10: ...e standard earhook with your thumb to click it off the processor 1 2 Insert the Cochlear EAC200 Series Screwdriver into the hole in the processor unit plug 3 Use the screwdriver to carefully remove th...

Page 11: ...ok into place 4 Align the speaker unit plug with the end of the earhook and carefully slide the plug into the processor 5 It should click securely into place If necessary carefully push it until you f...

Page 12: ...12 12 Care...

Page 13: ...Every day Clean the earmould and speaker unit cable with the supplied brush or a soft dry cloth Wipe any traces of wax away from the opening of the vent Check if the vent is clogged and use the suppl...

Page 14: ...for replacing Power Domes and add the following step Pull the dome off using your fingernails if necessary and discard 1 Push the new dome directly onto the speaker unit 2 Click it securely into place...

Page 15: ...a WaxStop filter Power and Plus Domes must be worn with a WaxStop filter in the speaker unit Remove a WaxStop tool from its shell One end of the tool has a new filter and the other has a removal tool...

Page 16: ...16 Pull the used filter out slowly keeping the tool straight 3 Flip the tool and push the new filter into the sound outlet Carefully pull the tool free and dispose of the used tool and filter 4...

Page 17: ...y if there is any discomfort or pain e g if device becomes hot or sound is uncomfortably loud and inform clinician Carer must routinely check the device for signs of overheating and for signs of disco...

Page 18: ...for children Do not allow children to replace an acoustic component without adult supervision Keep all parts of the acoustic component out of reach of children Removable parts e g Power Plus domes and...

Page 19: ...lycarbonate Processor covers are made of polystyrene and polycarbonate Coil covers are made of polycarbonate Hybrid materials for outer sheathing of the housing adaptor and the outer cable sheathing i...

Page 20: ...20 Legal statement The statements made in this guide are believed to be true and correct as of the date of publication However specifications are subject to change without notice Cochlear Limited 2014...

Page 21: ...21 COCHLEAR NUCLEUS 6 HYBRID HEARING SUPPLEMENT Notes...

Page 22: ...22...

Page 23: ...23 COCHLEAR NUCLEUS 6 HYBRID HEARING SUPPLEMENT...

Page 24: ...s Hybrid Invisible Hearing NRT Nucleus Off Stylet SmartSound SPrint the elliptical logo Nucleus in Chinese characters Codacs and myCochlear are either trademarks or registered trademarks of Cochlear L...