WARNING!

Failure to install or use this product according to manufacturer’s recommendations may result in property damage, serious injury, and/or death 

to those you are seeking to protect!

Do not install and/or operate this safety product unless you have read and understood the safety information 

contained in this manual.

1. 

Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to ensure the 

safety of emergency personnel and the public.

2. 

Emergency warning devices often require high electrical voltages and/or currents. Exercise caution when working with live electrical 

connections.

3. 

This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high current arcing, which 

can cause personal injury and/or severe vehicle damage, including fire. 

4. 

Proper placement and installation is vital to the performance of this warning device. Install this product so that output performance of the 

system is maximized and the controls are placed within convenient reach of the operator so that they can operate the system without losing eye 

contact with the roadway.

5. 

Do not install this product or route any wires in the deployment area of an air bag.  Equipment mounted or located in an air bag deployment 

area may reduce the effectiveness of the air bag or become a projectile that could cause serious personal injury or death.  Refer to the vehicle 

owner’s manual for the air bag deployment area.  It is the responsibility of the user/operator to determine a suitable mounting location ensuring 

the safety of all passengers inside the vehicle particularly avoiding areas of potential head impact.

6. 

It is the responsibility of the vehicle operator to ensure daily that all features of this product work correctly. In use, the vehicle operator should 

ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment doors), people, vehicles or 

other obstructions.

7. 

The use of this or any other warning device does not ensure all drivers can or will observe or react to an emergency warning signal. Never take 

the right-of-way for granted. It is the vehicle operator’s responsibility to be sure they can proceed safely before entering an intersection, drive 

against traffic, respond at a high rate of speed, or walk on or around traffic lanes.

8. 

This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws regarding 

emergency warning devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The manufacturer 

assumes no liability for any loss resulting from the use of this warning device.

IMPORTANT! This unit is a safety device, and it must be connected to its own separate, fused power point to assure its continued operation should any 

other electrical accessory fail.

Specifications:

Installation and Operation Instructions

CD9012 SERIES

Size:

0.99" dia. (lighthead only)

Weight: 

0.12 lb.

Input Voltage:

12-24 VDC

Op Temp:

 -40°C to 70°C (-40°F to 158°)

Model

Max Current (AMP)

Max Power (Watts)

CD9012AW

0.68

8.8

CD9012RB

0.52

6.6

CD9012BW

0.42

5

CD9012RW

0.5

6.4

CD9012W

1.2

15.5

CD9012-PI-RB

0.52

6.6

CD9012-PI-BW

0.66

8.4

CD9012-PI-RW

0.5

6.4

CD9012-PI-W

1.2

15.5

Summary of Contents for CD9012 Series

Page 1: ...bag deployment area It is the responsibility of the user operator to determine a suitable mounting location ensuring the safety of all passengers inside the vehicle particularly avoiding areas of pote...

Page 2: ...t Insert the twist lock lighthead through the socket and rotate it clockwise until it stops Make sure lighthead is tightly secured in the socket Figure 2 Figure 3 Single Color Flash Pattern Chart Tabl...

Page 3: ...Color 4 yes N C 16 28 Double 120FPM Ph1 Color 1 Synchronous Color 3 yes Class 3 17 29 Double 120FPM Ph2 Color 1 Synchronous Color 3 yes Class 3 30 Double 120FPM Ph1 Color 1 Alternately Color 4 yes N C...

Page 4: ...tal or consequential damages 920 0884 00 Rev A After installing the system it is best to do a POWER UP RESET the frst time to ensure that all heads are in sync Touch BLUE wire to ground while applying...

Page 5: ...aje adecuada que garantice la seguridad de todos los ocupantes del veh culo y deben evitar zonas que puedan provocar golpes en la cabeza 6 Es responsabilidad del operador del veh culo asegurarse de qu...

Page 6: ...ara sellarlo Fije el m dulo del controlador a un mazo de cables o una estructura de la carrocer a cercanos Realice las conexiones el ctricas como se describe a continuaci n Montaje en superficie Figur...

Page 7: ...0884 00 Rev A ROJO POSITIVO CAMBIAR SUMINISTRADO POR EL USUARIO FUSIBLE EN L NEA SUMINISTRADO POR EL USUARIO BLANCA POSITIVO AMARILLO Sincronizaci n AZUL TIERRA MOMENT NEA SELECCIONE PATR N DE PARPAD...

Page 8: ...n vitant en particulier les zones d impact potentiel de la t te 6 Il incombe l op rateur du v hicule de s assurer que toutes les fonctionnalit s de ce produit fonctionnent correctement au cours de l u...

Page 9: ...la sceller Attachez le module conducteur un faisceau de c blage ou une structure de carrosserie proximit Effectuez les branchements lectriques comme d crit ci dessous Surface de montage Figure 2 Choi...

Page 10: ...EUR BLANC POSITIF JAUNE Fonction de synchronisation BLEU MOMENTAN LA MASSE S LECTION DU MODE DE CLIGNOTEMENT POSITIF ATT NUATION EN MODE D AVERTISSEMENT UNIQUEMENT NOIR N GATIF COMMUTATEUR FOURNI PAR...

Page 11: ...Es liegt in der Verantwortung des Benutzers Bedieners einen geeigneten Montageort festzulegen um die Sicherheit aller Fahrzeuginsassen zu gew hrleisten und insbesondere Bereiche zu vermeiden in denen...

Page 12: ...Treibermodul in unmittelbarer N he eines Kabelbaums oder der Karosseriestruktur Stellen Sie elektrische Verbindungen her wie unten beschrieben Oberfl chenmontage Abbildung 2 W hlen Sie eine Stelle in...

Page 13: ...M LIEFERUMFANG ENTHALTEN WEI POSITIV GELB Synchronisiert BLAU KURZZEITIG GEGEN MASSE LEUCHTMUSTERAU SWAHL POSITIV NUR DIMMEN DES WARNMUSTERS SCHWARZ MASSE SCHALTER NICHT IM LIEFERUMFANG ENTHALTEN SCHA...

Reviews: