920-0451-00 Rev. A
Page 4 of 6
Glossary
ArrowStik® Emergency:
Only available in 1050 and 1051 series lightbars with Multi-Color rear light heads. This function
will flash the primary color lamps of the ArrowStik® modules in an alternating double flash sequence. When the LEFT,
RIGHT or CENTER-OUT function is activated the ArrowStik® sequence will cycle four times, then the primary color lamps
will alternate twice.
“Reset to Default” Box:
This will load the default lightbar flash configuration.
Load Configuration:
SmartPro Configuration Interface will open any previously saved configuration into current
program.
Null:
Light heads that are programed for Null pattern will not light up.
Pattern:
A repeated sequence and flash rate combination.
Primary Only:
For multi-color light heads there are primary color lamps and secondary color lamps. For single color light
heads there are only primary color lamps.
Primary Only
patterns will only light up the primary color lamps for both multi-
color light heads and single color light heads
Progressive Switch:
will use the Level-1 (L1), Level-2 (L1 + L2) and Level-3 (L1 + L2 + L3) modes.
Rate:
How fast the programmed light heads flash.
Read Device:
SmartPro Configuration Interface reads configurations from the SmartPro handheld device into the PC.
Read from Device:
SmartPro handheld device reads configurations from the lightbar into the SmartPro.
Save Configuration:
SmartPro Configuration Interface saves any changes you made to any of the drop down pattern
options.
Secondary Only:
For multi-color light heads there are primary color lamps and secondary color lamps. For single color
light heads there are only primary color lamps.
Secondary Only
patterns will only light up the secondary color lamps for
multicolor light heads. Any single color light heads will not light up.
Sequence
: repeated light heads flashing pattern.
Standard Flash Patterns:
For multi-color light heads there are primary color lamps and secondary color lamps. For
single color light heads there are only primary color lamps.
Standard Flash Patterns
will light up both the primary and sec-
ondary color lamps. Any single color light heads will not light up when secondary lights are suppose to flash.
Synchronized:
All light heads that are
Synchronized
together flash the same at the same time.
Unsynchronized:
All light heads flash at different times.
Write Device:
SmartPro Configuration Interface writes configurations from the PC into the SmartPro handheld device.
Write to Device:
SmartPro handheld device writes configurations from the SmartPro into the lightbar.