background image

920-0451-00 Rev. A

Page 4 of 6

Glossary

ArrowStik® Emergency:

 Only available in 1050 and 1051 series lightbars with Multi-Color rear light heads. This function 

will flash the primary color lamps of the ArrowStik® modules in an alternating double flash sequence.  When the LEFT, 

RIGHT or CENTER-OUT function is activated the ArrowStik® sequence will cycle four times, then the primary color lamps 

will alternate twice.

“Reset to Default” Box:

 This will load the default lightbar flash configuration. 

Load Configuration: 

SmartPro Configuration Interface will open any previously saved configuration into current

program. 

Null: 

Light heads that are programed for Null pattern will not light up. 

Pattern:

 A repeated sequence and flash rate combination. 

Primary Only:

 For multi-color light heads there are primary color lamps and secondary color lamps. For single color light 

heads there are only primary color lamps. 

Primary Only 

patterns will only light up the primary color lamps for both multi-

color light heads and single color light heads

Progressive Switch:

 will use the Level-1 (L1), Level-2 (L1 + L2) and Level-3 (L1 + L2 + L3) modes.

Rate:

 How fast the programmed light heads flash. 

Read Device: 

SmartPro Configuration Interface reads configurations from the SmartPro handheld device into the PC. 

Read from Device: 

SmartPro handheld device reads configurations from the lightbar into the SmartPro. 

Save Configuration:

 SmartPro Configuration Interface saves any changes you made to any of the drop down pattern 

options. 

Secondary Only: 

For multi-color light heads there are primary color lamps and secondary color lamps. For single color 

light heads there are only primary color lamps. 

Secondary Only 

patterns will only light up the secondary color lamps for 

multicolor light heads. Any single color light heads will not light up. 

Sequence

: repeated light heads flashing pattern.

Standard Flash Patterns:

 For multi-color light heads there are primary color lamps and secondary color lamps. For 

single color light heads there are only primary color lamps. 

Standard Flash Patterns

 

will light up both the primary and sec-

ondary color lamps. Any single color light heads will not light up when secondary lights are suppose to flash. 

Synchronized:

 All light heads that are

 Synchronized 

together flash the same at the same time. 

Unsynchronized:

 All light heads flash at different times.

Write Device: 

SmartPro Configuration Interface writes configurations from the PC into the SmartPro handheld device.

Write to Device:

 SmartPro handheld device writes configurations from the SmartPro into the lightbar. 

Summary of Contents for SmartPro

Page 1: ... Unit 02 Programming 03 Programming a Lightbar 03 Reading a Lightbar 03 Troubleshooting 03 Glossary 04 Notes 05 Warranty 06 IMPORTANT Read all instructions before installing and using Installer This manual must be delivered to the end user 1 Insert flash drive into the computer s USB port 2 After locating the flash drive on your computer screen click on the SmartPro_Configuration_Interface x x x x...

Page 2: ...ip Name file by Dept Name Unit Number or Lightbar etc 3 Click on save The resulting file will have the extension c3c Loading Configuration File 1 Loading a previously saved configuration file can be done in two ways a Double click the c3c file also shows the C3 logo you wish to load and the SmartPro application will launch with that configuration loaded b To manually load a file go to menu tab Fil...

Page 3: ...n right side of screen to see full options 2 Programming a i e Fast Quad pattern to my single color lightbar yields no flashing a Under the Pattern Selection tab check the drop down Level menus for chosen pattern b Was a Primary Only pattern section selected under the drop down menu c Scroll to see which section of the drop down is selected Make sure a Primary Only pattern is selected 3 My lightba...

Page 4: ...o Configuration Interface reads configurations from the SmartPro handheld device into the PC Read from Device SmartPro handheld device reads configurations from the lightbar into the SmartPro Save Configuration SmartPro Configuration Interface saves any changes you made to any of the drop down pattern options Secondary Only For multi color light heads there are primary color lamps and secondary co...

Page 5: ...920 0451 00 Rev A Page 5 of 6 Notes ...

Page 6: ...WARRANTIES Remedies and Limitation of Liability MANUFACTURER S SOLE LIABILITY AND BUYER S EXCLUSIVE REMEDY IN CONTRACT TORT INCLUDING NEGLIGENCE OR UNDER ANY OTHER THEORY AGAINST MANUFACTURER REGARDING THE PRODUCT AND ITS USE SHALL BE AT MANUFACTURER S DISCRETION THE REPLACEMENT OR REPAIR OF THE PRODUCT OR THE REFUND OF THE PURCHASE PRICE PAID BY BUYER FOR NON CONFORMING PROD UCT IN NO EVENT SHALL...

Reviews: