4.5 Pole Mount Bracket Installation Instructions
1.
Thread the mounting straps through the slots; use the outside slots for larger poles and
inside slots for smaller poles.
2.
Hold bracket to pole; Set the height of the bracket (C) so the speakerphone push
button(s) on the unit will be at desired height (please check with local codes for ADA
compliance).
3.
Band the bracket to the pole at desired height. To eliminate waste, pull band (A) from carton
as needed. With ears of buckle (B) away from operator, slide the buckle on the banding.
Lace banding around the object being clamped and again through buckle.
4.
Bend end of band under buckle.
5.
Slide band in tool nose slot. Press down on gripper with thumb and tension clamp by turning
the handle. Maximum tension has been reached when the band stops moving through the
buckle.
6.
When maximum tension has been reached, roll tool over buckle. At same time reverse the
handle carefully, with approximately a three-quarter turn to avoid breakage. The band that is
released will be used in the bend, therefore there is no loss of tension.
7.
Lift cutter lever and band will be cut to correct length. While holding the stub of the band
with your thumb, hammer flat over bridge of buckle.
8.
Complete application by hammering the buckle ears over the stub.
9.
Attach enclosure to bracket. Place a rubber washer (D) on each of the four studs.
10.
Place a second set of rubber washers on to each of the four studs (inside the unit).
11.
Place a steel washer (E) on each of the four studs.
12.
Turn a nut (F) on each of the four studs.
Note: All wiring must be installed and connected by experienced and certified personnel to meet
local and national electrical codes, and will include a service disconnect. Specifications subject to