background image

 A

For the reader cable connection to the CODE Controller, CAT 5 cable or 8 core 
twisted pair cable can be used.

B

The reader is normally installed at the right side of the door (outside) at a height 
of 1.4m from the floor and 3-5 cm from the door frame, with the exit button 
(inside) also at a height of 1.4m off the floor.

C

The reader should not be installed against a metal surface. If this can not be 
avoided, either the metal surface should be removed, with only the fixing area 
remaining, or an isolation material thicker than 10cm should be placed 
between the reader and the metal surface.

D

The Controller to reader length should not exceed 60 metres using CAT 5 cable 

E

Please observe reader power polarity when connecting to the access controller

Notes For Installation

Product Specification

Reader Parameters

  

Reader Radio Frequency: 13-56 MHz

  

Card Identification Mode: MF card

  

Sensing Distance: MF Card 2-4cm

  

Reader Data Output: Wiegand 26 Bit

  

Reading Speed: < 0.1s

Name 

Qty Note

CODE-2641 

Vandal Reader

User manual 

User Documentation

Screw driver 

1  

Φ

20mm×60mm,Special for RF006

Rubber plug 

2  

Φ

6mm×30 mm, used for fixing

Self tapping screws  2  

Φ

4mm×28 mm, used for fixing

Material  

Metal

Operating Voltage 

9-16V DC

Output  

WG 26

Card type  

Mifare 

Reading Distance  

2-4 cm

Communication Distance  

60M

Idle Current  

<80mA

Operating Temperature  

-45

ºC ~ 

60

ºC

Operating Humidity 

10%- 90% RH

Waterproof 

Conforms to IP68

Dimension 

120X56X18 mm

Packing List

Specification

Reviews: