4/14/2016
D014465 CR1400 CR1000 CR2300 CR2600 CR3600 CR44X5 CR8000 CR900FD CR6000 CR5000 T500 Client Version ICD
Page 58 of 106
© 2013-2016 The Code Corporation
12393 South Gateway Park Place Suite 600, Draper, UT 84020
(801) 495-2200
FAX (801) 495-0280
Reg Setting Name
Default (Hex)
Comment
C6
Auto Connect Mode
1
0: No Auto Connect - connect only on “X” and “:” commands
and upload events
1: Auto Connect - attempt to establish connection when in idle
mode and maintain connection when in standby mode
2: Auto Reconnect - attempt to connect when there is data to
send but only within specified time of last valid connection.
3: Auto Connect If Cabled - attempt to connect if Reader is
cabled or in charger
Bluetooth® readers: Also see register 76. Reader will not allow
the user to set auto-reconnect on, and store data. If any
setting that allows storing data is turned on, auto-reconnect
will be turned off, if it is on.
Keywords: #DataRetention
C7
Decoder Wide field
(FOI 1) Width
280
(#640)
Valid Range: 1 to 280 (#640) pixels
Decoder uses only the specified pixel height in the Wide field
(FOI 1). See section 9.2
C8
Decoder Wide field
(FOI 1) Height
3C0
(#960)
Valid Range: 1 to 3C0 (#960) pixels
Decoder uses only the specified pixel height in the Wide field
(FOI 1). See section 9.2