Reg Setting Name
Default (Hex)
Comment
2C6 Keyboard minimum
inter-character delay
(ms)
0
Valid Range: 0; 3 to 7FFFFFFF (#2147483647) Milliseconds
Require at least this amount of time between characters sent
over a keyboard interface. Any value below 3 ms will have no
noticeable effect.
Keywords: #InterCharacterDelay
2C7 Keyboard minimum
inter-scancode delay
(non-release scancode)
(ms)
0
Valid Range: 0; 3 to 7FFFFFFF (#2147483647) Milliseconds
Require at least this amount of time since the last scancode
sent over a keyboard interface (this setting is used when the
scancode to be sent is not a release scancode). Any value
below 3 ms will have no noticeable effect.
Keywords: #InterCharacterDelay
2C8 Keyboard minimum
inter-scancode delay
(release scancode) (ms)
0
Valid Range: 0; 3 to 7FFFFFFF (#2147483647) Milliseconds
Require at least this amount of time since the last scancode
sent over a keyboard interface (this setting is used when the
scancode to be sent is a release scancode). Any value below 3
ms will have no noticeable effect.
Keywords: #InterCharacterDelay
2C9 Enable vibrate in stand 0
0: Disabled
1: Enabled
If Enabled, this setting will allow the reader to vibrate when in
the stand. The default is to prevent vibration of the reader
while in the stand.
Note: Readers with a vibration motor are the CR1400,
CR1400XHD, CR1428, CR2600, CR2600XHD, CR3600,
CR3600DPM and CR6000.
Keywords: #Stand, #Vibration