Set / Change / Delete the Sub-Master and User Code 
Select between repeated use and single use codes 
Restrict the locked time 
 

Sub-Master Code can:

 

Open the lock 
Change the Sub-Master 
Set / Change / Delete the User Code 
 

User Code can:

 

Open the lock 
Change the User Code 
 

A code cannot be programmed into more than one level

 

 

Lost Code procedure

 

Note:

  The procedure require the door to be open 

 

Remove the rear-fixing bolts and and remove the lock from the door.  

 

Remove one battery.  

 

Press and hold the 1 button, replace the battery, the blue LED will flash twice, release the 
1 button. Within three seconds press the 1 button three times. The blue LED will flash 
twice and the lock will have reverted to the factory Master Code 11 33 55 77  and all 
other stored settings will be erased. 

Penalty Time

 

Entering three incorrect codes will cause the lock into shutdown for 10 seconds. 
 

Battery Power

 

The Cabinet Lock should provide well in excess of 40,000 openings of 4 seconds each, from 2 x 
AAA 1.5v cells. 
 

Low Battery

 

When the battery power is low the Red LED will flash 3 times before the Blue LED flashes to 
signal acceptance of the code. Batteries should be changed as soon as this happens. 
The lock will operate for 100 times with low battery. 
 

Battery failure override 

Summary of Contents for CL1200

Page 1: ...ction for the application A Repeated Use Important Note This is the default function and is already pre programmed in new locks This is the most common function and is used where the same code will be repeatedly used B Single User Locker Mode The User enters a single use code which will lock and then open the lock once only and then be erased This function is used for short term multi occupancy ap...

Page 2: ...e LED will flash twice release the 1 button Within three seconds press the 1 button three times The blue LED will flash twice and the lock will have reverted to the factory Master Code 11 33 55 77 and all other stored settings will be erased Penalty Time Entering three incorrect codes will cause the lock into shutdown for 10 seconds Battery Power The Cabinet Lock should provide well in excess of 4...

Page 3: ... the negative contact on the lock See image Enter the Master Code The lock will now withdraw the locking pin allowing the lock to open Fit new batteries by removing the upper fixing bolt and swinging the lock down over the edge of the door Refit the lock PROGRAMMING To program the lock must be in the open position with the badge button visible Every program command must commence by pressing the ba...

Page 4: ...ETE SUB MASTER CODE Master Code 05 05 Example 11335577 05 05 RESULT Sub Master Code deleted Sub Master Code Commands CHANGE THE SUB MASTER CODE Sub Master Code 06 New Sub Master Code New Sub Master Code Example 87654321 06 10101010 10101010 RESULT Sub Master Code has been changed to 10101010 SET OR CHANGE THE USER CODE Sub Master Code 07 User Code Example 87654321 07 6666 RESULT New User Code 6666...

Page 5: ...Master Code 10 number of hours lock to remain locked Example 11335577 10 04 RESULT The lock will auto open after 4 hours from locking Note 1 Restricting the locked time only works when the lock is in B single use locker mode 2 The lock can be set to auto open at the following hourly intervals 02 04 08 10 12 See above example for programming reference CHANGING FROM B SINGLE USE LOCKER MODE TO A REP...

Reviews: