B) Single Use Mode (locker mode)
A) REPEATED USE MODE (FACTORY DEFAULT)
User Code
•
New User Code
•
New User Code
••
Example:
2244
•
5541
•
5541
••
RESULT
User Code now 5541
B) CHANGING FROM REPEATED USE MODE A) TO B) SINGLE USE (LOCKER
MODE)
Master Code
•
09
••
Example:
11335577
•
09
••
RESULT
Lock will now operate as B) single use (locker mode)
RESTRICT THE LOCKED TIME
Master Code
•
10
•
(number of hours lock to remain locked)
••
Example:
11335577
•
10
•
04
••
RESULT
The lock will auto open after 4 hours from locking
Note:
1. Restricting the locked time only works when the lock is in B) single use (locker mode)
2. The lock can be set to auto open at the following hourly intervals 02, 04, 08, 10, 12. See above
example for programming reference.
CHANGING FROM B) SINGLE USE (LOCKER MODE) TO A) REPEATED USE
MODE
Master Code
•
11
••
Example:
11335577
•
11
••
RESULT
Factory set multiple use User Code 2244 will work repeatedly until reprogrammed
.