2.
Remove the lampholder assembly “
B
”.
3.
Identify the lampholder “
C
“.
4.
Fit in the lamp “
D
” in the lampholder pressing on the 2 terminals and position the welding of the glass “
E
” towards the back side of
the unit. The lamp used is manufactured from quartz glass and should be handled with care; always adhere to the instructions supplied
in the lamp’s packaging. Never touch the glass directly, use the tissue provided in the lamp’s packaging. DO NOT USE UNDUE FORCE.
5.
Replace the lampholder assembly in its original position and refasten the two screws “
A
” which were previously removed.
9.2. Aligning the lamp in the optical path
Aligning the lamp in the optical system is achieved via the 3 adjusters at the rear of the projector. This procedure should be undertaken
to maximise output, properly align the lamp in the optical system and to avoid the possible overheating of the internal components due
to the incorrect focusing of the beam onto components not intended to be exposed to this.
Alignment procedure
The lamp should be on, black-out and dimmer fully open, and no colours selected. If the lamp is not correctly aligned, a hot-spot will be
readily noticeable. Using the 3 adjusters in unison, you will need to bring the hot-spot to the centre of the beam and then flatten the
beam to maximum uniformity.
Unscrew the two knobs “
A
”, move it until the correct vertical and horizontal alignement is achieved and close them again.
Screw “
B
“ moves the entire lamp assembly axially within the unit; rotate it until correct positioning is achieved, resulting in a flat, even
beam.
LO
O
S
E
N
TO R
E
-L
A
M
P
Do not install on flammable surfaces.
Min distance from flammable materials to all exterior surfaces: 0.5m.
The lamps can be re-ignited only after 10 minutes. Do not attempt hot restrike.
Important safety information, see instruction manual before use.
LO
O
S
E
N
TO R
E
-L
A
M
P
LO
O
S
E
N
TO R
E
-L
A
M
P
LO
O
S
E
N
TO R
E
-L
A
M
P
ATTENTION!!
Each time you change the lamp, we recommend the following be carried out:
• realign the lamp in the optical path to avoid overheating dichroics and/or gobos .
• reset the lamp life counter (as described in section 8.8. Resetting the counter).
18