5.3. Mains connection
Mains cable characteristics
The mains cable provided is thermally resistant, complying to the most recent international standards. It meets or exceeds VDE and IEC norms, IEC
331,IEC 332 3C,CEI 20 35.
NB: In case of cable replacement, similar cable with comparable thermal resistant qualities must be used exclusively (cable 3x1.5 ø external
10 mm, rated 300/500V, tested to 2KV, operating temperature -40° +180°,
Coemar
cod. CV5309).
Connecting to mains power
For connection purposes, ensure your plug is of a suitable rating to sustain the maximum current:
•208/230/240V
8 amps constant current in normal operation
Locate the mains cable which exits the base of the unit and connect as shown below:
ATTENTION!!
• The use of a thermal magnetic circuit breaker is recommended for each projector. Strict adherance to all regulatory
norms is higly recommended.
• iSpot S should never be supplied mains power via a Dimmer; this is potentially dangerous.
• Prior to powering up the projector, ensure that the model in your possession correctly mathces the mains supply avai-
lable to you.
• A good earth connection is essential for the correct operation of the iSpot S. Never connect the projector to main
power if the green/yellow earth cable is not correctly connected
• All cable and plug connections should be carried out by fully qualified and licenced personnel only.
ground
neutral
live
brown
blue
yellow/green
main
8
English