Connecting the ballast to the Panorama C
yc 1800
A
rchitectural
The projector is designed for fixed installations and should therefore be connected to mains according to the normal regula-
tory conditions applicable in the country of installation.
The following is all the information required to ensure proper and correct connection of mains to the ballast and the con-
nection of the ballast to the projector.
7.1 Preparing mains cable
The mains cable used to power up the
Panorama C
yc 1800
A
rchitectural
should be 2 core + earth with conductor
dimension Ø 2,5 mm
2
and should be connected to the ballast.
External dimensions should be between 5 and 12 mm
2
to be fitted using the PG 13,5 connector used on the ballast.
External sheath properties should be suitable according to the position in which the cable is to be used and in accordance
with local electrical authority regulatory norms.
Your
coemar
service centre has available cables which suit this purpose: CV 03 (FG7) with properties which are suitable for
installation in exposed conditions and non-flammable.
For cable lengths greater than 10 m refer to specialist personnel noting that the current draw through the two cores is 9
Amps.
7.2 Preparing the cable connecting ballast to body
The cable used between the ballast and the
Panorama C
yc 1800
A
rchitectural
body varies according to the length being
utilised.
For standard lengths up to 10 m properties should be as follows:
Core 1: Ø 4 mm
2
Core 2: Ø 1,5 mm
2
Core 3: Ø 1,5 mm
2
Core 4: Ø 1,5 mm
2
Core 5: Ø 4 mm
2
Core 6: Ø 1,5 mm
2
Core 7 Earth: Ø 2,5 mm
2
color yellow/green
The external cable diameter should be between 13 and 18 mm
2
to allow use with the PG 21 connectors used on the ballast
and the projector body.
External sheath properties should be suitable according to the position in which the cable is to be used and in accordance
with local electrical authority regulatory norms.
Your
coemar
service centre has available cables which suit this purpose: CV 39 with properties which are suitable for instal-
lation in exposed conditions and non-flammable.
For cable lengths greater than 10 m refer to specialist personnel noting that the current draw through the six cores is:
Core 1: 18 Amps (230V)
Core 2: 1 Amps (230V)
Core 3: 0,3 mA (12V)
Core 4: 0,3 mA (12V)
Core 5: 18 Amps (230V)
Core 6: 1 Amps (230V)
Core 7: Earth: Ø 2,5 mm
2
color yellow/green
7.3 Connecting the mains cable
1) Open up the ballast by removing the 4 bolts using an M 5 hex key
7. Mains connection
English