Par Lite Led IP
can operate in three modes:
1.
using DMX512 control signal
2.
automated “STAND ALONE” or “MASTER/SLAVE” modes (see chapter
9. AUTO function
)
3.
using an IR remote in either “STAND ALONE” or “MASTER/SLAVE” (see chapter
10. IR function
)
6.1. Connecting DMX signal
Control signal is digital and is transmitted via two pair screened cable, as recommended in international standards for the transmission
of DMX512. Connection is serial, utilising the XLR3 sockets located on the rear panel of the
Par Lite Led IP. Coemar
supplies the unit
with XLR3 connectors with an IP67 protection rating; use only similar plugs for the connection of signal to the unit, thereby ensuring
that the protection rating of the
Par Lite Led IP
is maintained.
Signal connection via the XLR3 connectors
Connection is to international standards. Connection is as indicated below:
pin 1 = GND
pin 2 = data -
pin 3 = data +
Should your DMX 512 controller output signal via a cannon XLR5 (5 pin), pins 4 and 5 should remain unconnected.
6.2. Powering up
After having followed the preceding steps, turn on mains power on to the unit.
The
POWER
led located near the dip-switch panel will come on.
Turning on power with DMX signal connected.
The yellow DMX led will flash to indicate that
DMX 512
is being correctly received. If the yellow led is off, DMX signal is not being
received (see section
16. Frequently asked questions
).
ATTENTION!!
Ensure that all data conductors are isolated from one another, the screening and the metal housing of the connector.
Pin number 1 and the housing should never be connected to mains power.
3
2
1
Controller
Standard
DMX 512
OUT
out
in
Ad altri
Par Lite Led
Connect to other
Par Lite Led
out
in
6. DMX signal functions
11
English