English
23
10.1 How to fix the optional accessories holder
1 Open the upper casing of the unit by unscrewing the 4 screws, temporary remove the two side plates “A”.
2 Insert the gel frame holder in site as explained in the picture and fix again the two plates “A” .
3 Close the unit by repeating to the contrary the step 1 of this procedure.
11. Maintenance
11.1 Periodic clearing
Polycarbonate screen
Even a fine layer of dust can reduce the luminous output and alter the compactness of the beam. Regularly clean all filters and
lenses using a soft cotton cloth, dampened with a specialist lens cleaning solution.
Cleaning of the unit
Use a soft brush or a common vacuum cleaner or a source of compressed air for removing dust. For the cleaning of the housing
use a soft cloth and a non-aggressive cleaner. Check that the internal fans and heat exchanger must be perfectly clean.
11.2 Special controls
How to top up the water tank ( to perform every 1500 hours ):
1 Open the upper casing of the unit by unscrewing the 4 screws.
2 Locate the water tank which is site in the back-right of the unit, beside the mirror
3 Remove the cap from the tank and fill it up to the edge with bi-distilled water avoiding the formation of air bubbles.
4 Close tight the tank’s cap.
WARNING !
-Periodically check the water level in the expansion
tank; the tank must always be totally full.
-Check that the cap is well tightened.
-The lack of refrigerant can cause heavy damage to
the leds so to require their replacement.