background image

Coemar Lighting s.r.l.

Via Carpenedolo 90

 46043 Castiglione delle Stiviere, Mantova, Italia

tel. +39 0376/1514412 - fax +39 0376/1514380 

info@coemar.com

Coemar

 reserves the right to change specifications without prior notice

Summary of Contents for ReLite Led Kit T / D

Page 1: ...ReLite Led Kit T D ReLite Led Kit 150 version ...

Page 2: ...m you purchased your ReLite Led Kit this information will assist us in providing spare parts repairs or in answering any technical enquiries with the utmost speed and accuracy WARNING the security of the fixture is granted only if these instructions are strictly followed therefore it is absolutely necessary to keep this manual User Manual version 1 3 Edition January 2020 ReLite Led Kit T D ...

Page 3: ... Pag 9 5 3 Supply cable characteristics Pag 9 6 Control signal connections Pag 10 6 1 Control signal connection by XLR5 plugs Pag 10 7 Turning the projector on Pag 11 7 1 DMX address of the unit Pag 11 8 DMX chart Pag 12 8 1 DMX Chart 5 1 channels Pag 12 9 Display panel functions Pag 13 9 1 Quick guide to menu Pag 13 9 2 Rapid count Pag 13 9 3 Quick CCT menu Pag 14 9 4 Main functions menu Pag 15 9...

Page 4: ...ax or e mail and inform them you will formally notify them in writing through registered letter Packing list Make sure the packaging contains 1 ReLite Led Kit 1 Instruction manual 2 General information 2 1 Important Safety information Fire prevention 1 Never locate the fixture on any flammable surface 2 Minimum distance from flammable materials 0 5 m 3 Minimum distance from the closet illuminable ...

Page 5: ...D was turned off 2 Never install the fixture in an enclosed area lacking sufficient air flow the room tempera ture must not exceed 45 C 3 The projector contains electronic and electrical components which must under no circum stances be in contact with water oil or any other liquid Failure to do so will compromise the proper functioning of the projector 2 2 Warranty conditions 1 The fixture is unde...

Page 6: ...n the fixture Color temperature Tungsten 3 200 K Daylight 5 600 K Color Rendering Index CRI 90 or 95 Weight Depending on the ReLite Led group Operating Ta C F range 20 to 45 C 4 to 113 F two thermal protection at 95 C 203 F LED and 85 185 F Board Connectors G22 GX9 5 G38 GY9 5 GY16 Custom IP rating 20 3 2 Dimensions 190 mm 7 48 in 110 mm 4 33 in 73 mm 2 87 in 210 mm 8 26 in 124 mm 4 88 in 90 mm 3 ...

Page 7: ...Italiano 7 3 3 Unit s main components A Components description A Display panel B DMX In C DMX Out D PowerCon In E PowerCon Out F Skintop B C D E F ReLite Led Kit 150 version ...

Page 8: ...life to your projector simply replacing the old lamp with the ReLite Led group The ReLite Box can be fixed to your projector s yoke through the fixing plates present on the box A A Warning Always ensure that your support structure and fixing bolts clamps etc are rated to support the weight of the fixture ...

Page 9: ...nge for the use of ReLite Led Kit All connections should be carried out by a suitably qualified personnel 5 2 Connection to mains power Mains cable characteristics The mains cable provided is thermally resistant complying to the most recent International standards Note in case of cable replacement similar cable with comparable thermal resistant qualities must be used exclusively cable 3 X 1 5 ø ex...

Page 10: ... be connected to the power supply unit 6 1 Control signal connection by XLR5 plugs The digital control signal is transmitted to the projector via a two pole cable screened in according to the Inter national standards for DMX 512 data transmission The connection must be serial using connectors XLR5 male and female located on the back of ReLite Led Kit labelled DMX512 IN e OUT DMX In DMX Out ...

Page 11: ...eLite Led Kit also uses 5 DMX channels which means that it will respond to the commands from channel 1 to channel 5 of your DMX 512 controller Accordingly a second unit should be addressed as A006 a third one as A011 and so on The operation must be carried out on every ReLite Led Kit which has an address different from A001 Altering the DMX address 1 Press the or button until the display shows the...

Page 12: ... effect with variable speed from slow to fast 162 207 64 81 step stop strobe 208 209 82 82 proportional random strobe effect with variable speed from slow to fast 210 255 82 100 5 special functions step no effect 0 9 0 4 600Hz 10 84 4 33 fan at low noise speed 85 96 33 38 fan at auto silent speed 97 108 38 42 proportional fan speed control 109 120 43 47 step no effect 121 133 47 52 enables the aut...

Page 13: ...nctions of the projector so that it will respond differently to the controller therefore carefully read about the functions described here before carrying out any possible selection 9 2 Rapid count Through the display panel of ReLite Led Kit it is possible to quickly change the various numbers displayed for the different functions in the following 3 manners 1 Pressing the or buttons will cause the...

Page 14: ... dimmer menu By pressing the enter button the user will enter the quick dimmer menu thanks to this menu it will be possible to increase and decrease the light intensity in steps of 10 in a range from 0 to 100 0 20 10 90 100 ...

Page 15: ...le Dimmer sets the luminous intensity Strobe manually sets the strobe DMX channel Store stores the modifications that will be set at the next times the fixture will be turned on Auto under this setting the fan speed varies based on the overall temperature of the fixture to guarantee the maximum output possible Low noise this setting will keep the speed of the fan at the minimum level while the lig...

Page 16: ...ugh to push a button to unlock the keyboard it is necessary to hold any button down for a few seconds LED Frequency Allows to choose the operating frequency of the LEDs in order to avoid flickering issues with video recording devices The excursion varies from 611 Hz default to 19000 Hz Reset It allows to restore the default factory settings of the unit Keeping pressed both ENTER and MENU allows to...

Page 17: ...board temperature Volt Shows the power supply voltage DMX Input Shows the value of the DMX channels received by the fixture on every channel that the fixture occupies on the line Rate Shows the refresh rate of the DMX signal sent by the console Alarm This menu shows the alarm statuses if there is any tEMP Temperature vOLt Supply Voltage dM In DMX Input rAtE DMX Rate ALrM Alarms brd Board Temperatu...

Page 18: ...shows the overall hours of life of the fixture LED life shows the overall LED module life LED life reset shows the overall LED module life currently installed Note this items can be reset in case of LED module replacement Software version Shows the software version currently installed in the fixture LEd LED Status FrE LED Frequency FAn Fan Voltage HOUr Usage Hours vErS Software Version UnIt Unit l...

Page 19: ...ter should be considered for the exclusive use of technicians and qualified personnel 9 6 Electronic alignment of the leds The display panel of ReLite Led Kit allows the electronic alignment of the LEDs this procedure is performed by Coemar at the time of testing this procedure may be useful for special effects or in case of replacement of internal components PCBs LEDs etc Altering the settings ma...

Page 20: ...off after 10 minutes of fixture inactivity Error code Description noal No Alarm No alarm The projector self diagnostic routine didn t find any issue DTER Data Error Data error Initial data loading has failed the projector loaded the default data settings restart the fixture again and if the error persists contact the Coemar as sistance center ADER Address Error Address error The projector does not...

Page 21: ... worn parts Question Possible solution ReLite Led Kit does not emit light Projector not powered Make sure the power cord is plugged in or test the input voltage in the projector in which ReLite Led Kit is installed Make sure the ReLite Led Kit is well inserted into the socket The following list shows common issues that may be simply solved If issues persist the unit must be repaired by qualified p...

Page 22: ...Italiano 22 User notes ...

Page 23: ...Italiano 23 User notes ...

Page 24: ...enter for waste electrical and electronic equipment The treatment and disposal of environmentally friendly helps prevent potential negative environmental and health and promote the reuse and or recycling of materials making up the equipment Illegal disposal by the user includes the application of administrative sanctions provided by law ...

Page 25: ...Lighting s r l Via Carpenedolo 90 46043 Castiglione delle Stiviere Mantova Italia tel 39 0376 1514412 fax 39 0376 1514380 info coemar com Coemar reserves the right to change specifications without prior notice ...

Reviews: