9.4 Instructions for regenerating descaling filter
The instructions given below should be followed to regenerate the descaling filter:
1.
Place a container with a capacity of at least 2 litres under pipe
E
. Move levers
C
och
D
from left to right.
2.
Remove the lid by unscrewing knob
G
and put salt (normal kitchen salt) in descaling filter (pos. 5): 1
kg for 8- litres descaling filter and 2 kg for 16-litres descaling filter.
Then refit lid and move tap lever
C
from right to left (fig. 6) so that the salty water can flow through pipe
F
.
When the water is pure, reset lever
D
from right to left (fig. 7). Shake filter meanwhile regeneration
goes on.
IMPORTANT!
Regeneration must be done every 15 days for a daily coffee consumption of between 1 and 2 kg.
If consumption is greater than this, regeneration should be done every 7 days.
See instructions for descaling filter.
N.B.
It is very important to regenerate the descaling filter. Failure to regenerate the resins in the descaling filter
causes calcification in the boiler, the solenoid valves and the hydraulic circuit.
These deposits have a negative influence on the machine´s performance and reliabillity and can even
cause serious damage which will lead to the intervention of the assistance service for cleaning the
boiler.
15.
9.
Maintenance
Crema Compact och Digital
FIG. 5
FIG. 6
FIG. 7