17.
Fault:
Problem:
The water level control provides water when it should not.
Cause 1:
The level sensor/control centre electrical connection is broken.
Cures:
Repair.
Cause 2:
The frame earthing/control centre electrical connection is broken.
Cures:
Repair.
Cause 3:
The level sensor is dirty.
Cures:
Clean. When dismantling do not unthread it from the insulator but remove it complete with the union.
Cause 4:
The electronic control centre is defective.
Cures:
Replace.
Problem:
The water level control provides water when it should not.
Cause 1:
The solenoid valve coil is defective (earth fault).
Cures:
Check and replace if necessary.
Cause 2:
The solenoid valve lifter is blocked.
Cures:
Check and replace solenoid valve if necessary.
Problem:
The water in boiler is still filling up and the safety valve leaks out water.
Cause 1:
Level sensor is not connected.
Cures:
Check and replace if necessary.
Cause 2:
There is a contraries object inside the solenoid valve and the automatic level regulation.
Cures:
Check and replace if necessary.
Cause 3:
Gasket is trayed.
Cures:
Check and replace if necessary.
10. Faults and routine repairs
Crema Compact och Digital