Picture
description
Connect the water-hose from the dispenser to the
cold water mains (do not forget seals).
Turn on the water and check for leaks.
Note!
It is strongly recommended to use some sort of
water isolator in the water line in case of an
emergency leakage.
Connect the power-plug to the wall socket.
Now the compressor starts and the front panel
lights up.
The water pressure is factory adjusted to
2.2 bar, which is the correct working pressure.
Check by pressing and holding one product button and
reading the manometer. If there is variations adjust by
pulling black knob and turn it until you get a reading of
2.2 bar.
9
Installation & User Instructions
Page 9
Connection to services