COFFE
tek
LTD
BEAN TO CUP
Issue 1
01/12/2005
22
INGREDIENT A (GRAMS PER SECOND)
VAL = 00001.05
(3) Press
¿
(UP) to increase the value or
À
(DOWN) to decrease it.
(4) Having set the new throw rate, press ENTER to enter the new value.
(5) Press
¿
(UP) to display the next ingredient.
(6) Press ESC to exit from the SET INGREDIENT THROW RATE option.
T
ANK
S
TATUS
22.
The TANK STATUS option allows the engineer to view the status of the boiler water level
and temperature.
(1) Press ENTER to display the tank status. The display will show:
PROBE IS WET
90 °C ADC = 380 (0,0)
The value 380 is a number corresponding to the temperature setting.
The value (0,0) is the element status.
(2) Press PROG to exit from the TANK STATUS option and access the next Engineer's
Program option.
I
NITIALISE
23.
The INITIALISE option allows the engineer to initialise the machine.
(1) Press ENTER. The display will show:
ARE YOU SURE?
ENTER (Y) MODE (N)
(2) Press ENTER to initialise the machine or PROG to access the next Engineer's
Program option.
C
HANGE
S
ETTINGS
24.
CHANGE SETTINGS allows alteration of the following machine settings:
DESIRED TEMP
90°C (380)
Allows setting of normal operating temperature.
TEMPERATURE LOW
77°C (0027)
Allows setting of low cut-out point.
Summary of Contents for BEAN TO CUP
Page 1: ...BEAN TO CUP BEVERAGE MACHINE TECHNICAL MANUAL ...
Page 5: ...COFFEtek LTD 5 01 12 2005 Issue 1 BEAN TO CUP This page is intentionally blank ...
Page 14: ......
Page 43: ...COFFEtek LTD BEAN TO CUP Issue 1 01 12 2005 42 Section 4 Exploded Parts Diagram ...
Page 44: ... wittern 88734_btc_but_6 dgn 27 01 2009 11 51 10 ...
Page 45: ......
Page 46: ......
Page 47: ......