FAULT FINDING GUIDE
FAULT
POSSIBLE CAUSE
ACTION
FATAL I
2
C ERROR
Displayed
Keypad does not bleep
Drinks cold
No motor operation
Machine inoperable;
no display
(a) Electrical
noise
(b) MPU
Board
fault
(c) Software
error
(a) Keypad
damaged
(b) Keypad
disconnected
(c) MPU
Board
fault
(a) Heater
fuse
blown
(b)
Thermal cut-out tripped
(c) Desired
temperature
incorrectly set
(d)
Excessive scaling in heater
tank
(e)
Solid state relay fault
(f)
Low cut-out in program
incorrectly set
(g) Temperature
probe
wet
(a) Jammed
motor
(b)
Power Supply failure
safety
trip
(a) Power
Supply
failure
(a) Check
motors
(b)
Replace MPU Board
(c) Reset
power
(a) Replace
keypad
(b) Reconnect
(c)
Replace MPU Board
(a)
Check and replace
(b) Reset
trip
(c) Check
desired
temperature
setting
(d)
Check tank and descale if
necessary
(e) Check
relay
(f)
Reset low cut-out setting
(g)
Dry probe and check
for
leaks.
(a) Check
motor
operation
(b) Reset
power
(a) Replace
Power
Supply
Board
Summary of Contents for BEAN TO CUP
Page 1: ...BEAN TO CUP BEVERAGE MACHINE TECHNICAL MANUAL ...
Page 5: ...COFFEtek LTD 5 01 12 2005 Issue 1 BEAN TO CUP This page is intentionally blank ...
Page 14: ......
Page 43: ...COFFEtek LTD BEAN TO CUP Issue 1 01 12 2005 42 Section 4 Exploded Parts Diagram ...
Page 44: ... wittern 88734_btc_but_6 dgn 27 01 2009 11 51 10 ...
Page 45: ......
Page 46: ......
Page 47: ......