13
Country Club Road
P.O. Box 779
Wadesboro, NC 28170 USA
TEL: (800) 477-5003
FAX: (800) 374-6853
Figure 9A — Wiring Diagram for 115/230V - 1 Phase Models
TROUBLE SHOOTING CONTINUED
1.
Brake needs adjustment
1. See BRAKE ADJUSTMENT, page 9.
2.
Broken shading coil on brake frame
2. Replace shading coil or complete brake frame assembly.
Motor brake “buzz” (anytime hoist is running)
1.
Brake needs adjustment
1. See BRAKE ADJUSTMENT, page 9.
2.
Low voltage
2. Ensure that the voltage at the reversing contactor is within ±10% of the nominal voltage while lifting a load.
Motor brake noise or chatter (while starting hoist)
1.
Hoist overloaded
1. Reduce load to within rated capacity of hoist.
2.
Brake dragging
2. Check for proper brake adjustment or other defects.
3
Low voltage
3. Ensure that the voltage at the reversing contactor is within ±10% of the nominal voltage while lifting a load.
4.
Overload limiting clutch intermittently slipping
4. Replace overload clutch assembly.
Lack of proper lifting speed
For more information contact: Sievert Crane and Hoist, (708) 771-1600, parts@sievertelectric.com, www.sievertcrane.com