40
CHAPTER 3
®
press the
Enter
key to confirm the data;
on the display is shown the message: "Enter New PIN";
enter the new PIN by using the
<< >>
keys;
press the
Enter
key to confirm the data;
5 Account Parameters
[Operator (
)]
The menu foresees the following items:
•
5.1 Max Cash Cred.;
•
5.2 Max. Key Cred.;
•
5.3 Max. Distrib.;
•
5.4 Decimals;
•
5.5 Base Step.
5.1 Maximum Cash Credit
This menu item sets the maximum cash credit beyond which the bill and the coin acceptance of
the Coin Mechanism is inhibited.
The values must be included between 0.00 and 649.99. With the value set at zero, the cash is
accepted only with the insertion of the key. As a default the data set is 3.00.
5.2 Maximum Key Credit
This menu item sets the maximum credit limit beyond which it is no more possible to credit any
amount on the key, but to carry out sale operations. When the key maximum credit is reached
the Bill Validator and the Coin Validator are inhibited. The values must be included between
0.00 and 649.99. As a default the data set is 15.00.
5.3 Maximum Distributable
It is the limit beyond which no change is given. This is the condition even though the change
button is pressed on the Coin Mechanism or when the operation mode set is single sale. The
values must be included between 0.00 and 649.99. As a default the data set is 3.00.
5.4 Decimals
It sets the number of decimal digits necessary for the management of the preset currency. The
setting range is included between 0 and 3. As a default the data set is 2, which corresponds to
the 0.00 display. On the display of the Coin mechanism is indicated the number of decimal digits
set and the corresponding display.
5.5 Base Step
The base step is the measure used to calculate and communicate to the machine the sale prices
(usually it represents the smallest value of the currency managed). It is calculated by
considering the decimal digits (ex: base step at 1 with 2 decimal digits = 0.01). The parameter is
particularly important in the price management in “Prices in VMC” and “Cost by Price” modes,
as it limits the value of the prices which can be managed by the System (ex.: with base step
0.01 = the max. price to be managed is 2.40 Euro; for higher amounts - up to about 12.00 Euro -
it is necessary to set the step at 0.05). The setting range is included between 1 and 255. As a
default the data set is 1.
Decimals
2
0.00
Base Step
1
0.01