Install the M12 Lens
1. Verify that the 24VDC power supply is unplugged and not receiving power.
2. Determine the correct lens tool to use, based on the focal length of the lens.
Lens Focal Length
Cognex Lens Tool
6MM (LM 12-06-02)
8MM (LM 12-08-02)
12MM (LM 12-12-02)
16MM (LM 12-16-02)
Clear Anodized (P/N 820-0233-xR)
25MM (LM 12-25-02)
Black Anodized (P/N 820-0234-xR)
3. To install the lens, insert the lens and using your fingers, turn it clockwise. If needed, attach the lens tool and
finish tightening the lens; the maximum torque is 0.34 Nm (3 in-lb).
4. Reattach the lens cover.
5. Restore power to the 24VDC power supply and turn it on if necessary.
6
Uninstall and Install the M12 Lens