3 SPECIFICATIONS
3.1 General Specifications
15
3
3
SPECIFICATIONS
This chapter shows the specifications of code reader CF26s.
3.1
General Specifications
The following shows the general specifications of code reader CF26s.
*1 Do not install it in the following places:
⋅
Where the ambient temperature or humidity exceed the applicable ranges
⋅
Where condensation occurs due to sudden temperature changes
⋅
Where there is corrosive or flammable gas
⋅
Where there are a lot of conductible dust, iron filings, or salt
⋅
Where in danger of organic solvents, such as benzene, thinner, and alcohol or strong alkaline substances such as caustic soda to
adhere
⋅
Where subject to much vibration or shock
⋅
Where in danger of liquid such as water, oil, or chemicals to adhere
Item
Specifications
Ambient operating temperature
0 to 40
Ambient storage temperature
-10 to 60
Maximum humidity
Less than 95% RH, non-condensing
Vibration resistance
IEC 60068-2-6: A vibration of 10 G (10 to 500 Hz at 100 m/
with 15 mm width) was applied to each of the three
main axes for 2 hours.
Shock resistance
IEC 60068-2-27: 1000 half sinusoidal shocks with 11 G (10 ms) were applied.
Protective structure
IP65
Installation location
Outside a control panel
Summary of Contents for Mitsubishi Electric MELSENSOR CF26 Series
Page 2: ......
Page 14: ...12 1 PRODUCT OVERVIEW MEMO...
Page 30: ...28 4 FUNCTIONS 4 1 Function List MEMO...
Page 49: ...7 INSTALLATION 7 2 Registration of a Profile 47 7 MEMO...
Page 51: ...8 MAINTENANCE AND INSPECTION 8 3 Cleaning a Lens Cover 49 8 MEMO...
Page 53: ...9 TROUBLESHOOTING 9 1 Error Checking Method 51 9 MEMO...
Page 58: ...56 APPX Appendix 2 External Dimensions MEMO...
Page 59: ...APPX Appendix 2 External Dimensions 57 A MEMO...
Page 63: ......