5 SYSTEM CONFIGURATION
5.5 Available Modules and Configuration Tools
35
5
5.5
Available Modules and Configuration Tools
This section shows the configuration tools and modules that are available for connecting to a code reader CF26.
The available version of configuration tools and modules varies depending on whether or not the automatic detection function
of connected devices in GX Works3 is applied when setting a programmable controller.
The automatic detection function of connected devices can be applied in the programmable controller setting when
configuring settings for CC-Link IE Field Network Basic connection and SLMP scanner connection.
For the method of setting a programmable controller, refer to the following:
Code Reader Connection Guide
Modules
The following shows the modules and versions supported by a code reader CF26.
Configuration tool
The following shows the configuration tools and versions supported by a code reader CF26.
*1 When using the predefined protocol support function or the sensor/device monitor function, use the version "1.055H" or later.
*2 When using the predefined protocol support function, use the version "1.585K" or later.
*3 The firmware of a code reader CF26 needs to be updated to the version that supports DataMan Setup Tool.
For details on the firmware update, refer to the "How do I use the Update Firmware function?" on the "DataMan 260 Series: Questions
and Answers" screen. Select [Help]
[CF26]
[CF26 Questions and Answers] in DataMan Setup Tool to display the screen.
: the automatic detection function of connected devices is not supported.
Module
Version
With the automatic detection function of
connected devices
Without the automatic detection function
of connected devices
RnCPU, RnENCPU
The firmware version is 28 or later.
No restrictions
FX5CPU
The firmware version is 1.040 or later.
High-speed Universal model QCPU, Universal model
process CPU
The first five digits of the serial number are
'19042' or higher.
QnUDE(H)CPU
Built-in Ethernet port LCPU
The first five digits of the serial number are
'18112' or higher.
FX3UCPU
The firmware version is 3.10 or later.
Serial communication module
No restrictions
: the automatic detection function of connected devices is not supported.
Engineering tool
Version
With the automatic detection function of
connected devices
Without the automatic detection function
of connected devices
GX Works3
1.035M or later
No restrictions
GX Works2
1.565P or later
Code reader setup tool
Version
DataMan Setup Tool
DataMan Setup Tool 6.1.5 or later
Firmware 5.7.5 or later
Summary of Contents for Mitsubishi Electric MELSENSOR CF26 Series
Page 2: ......
Page 14: ...12 1 PRODUCT OVERVIEW MEMO...
Page 30: ...28 4 FUNCTIONS 4 1 Function List MEMO...
Page 49: ...7 INSTALLATION 7 2 Registration of a Profile 47 7 MEMO...
Page 51: ...8 MAINTENANCE AND INSPECTION 8 3 Cleaning a Lens Cover 49 8 MEMO...
Page 53: ...9 TROUBLESHOOTING 9 1 Error Checking Method 51 9 MEMO...
Page 58: ...56 APPX Appendix 2 External Dimensions MEMO...
Page 59: ...APPX Appendix 2 External Dimensions 57 A MEMO...
Page 63: ......