6 SYSTEM CONSTRUCTION
6.5 Connection of a Breakout Cable (COGNEX Product)
6.5
Connection of a Breakout Cable (COGNEX
Product)
This section shows the precautions and the procedure for connecting a breakout cable (COGNEX product).
Ex.
Breakout cable (COGNEX product): CCB-PWRIO-**
Precautions
• Check that the 24 VDC power supply is OFF when connecting with a breakout cable (COGNEX product).
• Cut unused wires or protect them with insulating materials. Be careful not to contact with 24 VDC wires.
• The breakout cables (COGNEX product) are designed to connect with their key aligned with the keyway of the connector
on a code reader. Do not force the connections or damage may occur.
• When powering ON the system, turn ON the power of the programmable controller first, or at the same time with the code
reader CF26.
For details of breakout cables, refer to the following:
Page 26 Breakout cable (COGNEX product)
Operating procedure
1.
Connect a breakout cable (COGNEX product) with a 24 VDC power supply.
Connect the breakout cable (COGNEX product) and terminals as follows: (7) 24 VDC (red) to a positive terminal, (8) GND
(black) to a negative terminal of the 24 VDC power supply.
2.
Connect the breakout cable to the power supply, I/O, and RS-232 connector of the code reader CF26.
(7)24 VDC (Red)
24 VDC
power supply
(8)GND (Black)
Summary of Contents for Mitsubishi Electric MELSENSOR CF26 Series
Page 2: ......
Page 14: ...12 1 PRODUCT OVERVIEW MEMO...
Page 30: ...28 4 FUNCTIONS 4 1 Function List MEMO...
Page 49: ...7 INSTALLATION 7 2 Registration of a Profile 47 7 MEMO...
Page 51: ...8 MAINTENANCE AND INSPECTION 8 3 Cleaning a Lens Cover 49 8 MEMO...
Page 53: ...9 TROUBLESHOOTING 9 1 Error Checking Method 51 9 MEMO...
Page 58: ...56 APPX Appendix 2 External Dimensions MEMO...
Page 59: ...APPX Appendix 2 External Dimensions 57 A MEMO...
Page 63: ......