SECTION 2: INSTALLATION
OPTION SWITCH SETTINGS
MAG bill acceptors contain an option switch bank on the
main logic board which allows the unit to be customized
to the requirements of the individual account. This switch
bank is factory set with switch 3 and 8 in the ON posi-
tion and 1, 2, 4, 5, 6, and 7 in the OFF position.
Setting Option Switches (see Figure 1)
Remove power from the bill acceptor. Remove the bill
box. Located on the side of the logic board cover is the
option switch access hole. Insert a small screwdriver
through the access hole to set the option switches as
desired (see Figure 2). Reinstall the bill box. Apply
power and test for proper operation.
Figure 2
Figure 1
MAG**SA Option Switch Settings
(see Figure 2)
MAG**B Option Switch Settings
(see Figure 2)
SWITCH
ON
OFF
1
High Security
Standard Acceptance
2
Accepts bills in one
Accepts bills in both
directions only (face
directions (face up)
up, green seal first)
3
Standard credit pulse Short credit pulse
150ms on 150ms off 50 ms on 50 ms off
4
$20 Accept
$20 Reject
5
$10 Accept
$10 Reject
6
$5 Accept
$5 Reject
7
$2 Accept
$2 Reject
8
$1 Accept
$1 Reject (see note)
NOTE:
The 407982 logic board with software
67090 will accept $1.00 bills with Switch 8 "OFF",
if no other bills are enabled. This is the maximum
accept mode.
If however, another bill switch is "ON", then $1.00
bills will be rejected if Switch 8 is "OFF".
INSTALLING THE BILL ACCEPTOR
1. Remove power from the vending machine.
2. Set the bill acceptor option switches as desired.
3. Connect the bill acceptor harness to the mating
harness in the vending machine.
4. Mount the bill acceptor according to the instructions
found in the vending machine manual or appropriate
kit literature.
NOTE: Ensure bill acceptor is free of all obstructions
5. Load the vending machine with product and fill the
coin changer with change.
6. Apply power to the vending machine.
7. Test for proper operation.
SWITCH
ON
OFF
1
High Security
Standard Acceptance
2
Accepts bills in one
Accepts bills in both
directions only (face
directions (face up)
up, green seal first)
3
Serial or Parallel
Pulse Interface
Interface
4
$20 Accept
$20 Reject
5
$10 Accept
$10 Reject
6
$5 Accept
$5 Reject
7
$2 Accept
$2 Reject
8
$1 Accept
$1 Reject
OPTION SWITCH
ACCESS HOLE
#8
#1
O
N
O
F
F
1
2
3
4
5
6
7
8