10
PART III
INITIAL CLEANING
PROCEDURE
This is a new machine and it must be completely disassembled,
washed, and sanitized before starting. Proceed, as follows:
1) Remove the mix tank cover and items packed in the tank
(spare parts, sanitizer, lubricant).
The spare parts or start-up kit will include: 1) a spatula, 2) spare
o-rings and rubber seals, 3) an o-ring extractor, 4) a tube of
sanitary lubricant, 5) three various sized cleaning brushes, 6)
several packets of sanitizer and the OPERATIONAL MANUAL.
HELPFUL SUGGESTION: Before proceeding with the
disassembly of the freezer, we recommend a plastic dish pan be
used in which to place the parts. This will minimize the possibility
of misplacing or damaging the various component parts.
2) Proceed with the disassembly process by removing the
gravity feed tube located in the mix tank. Snug fitting, the tube
can be removed by pulling straight up and out.
Once removed, the tube must be disassembled. To disassemble,
first remove the “SPLASH GUARD” by pulling it out of the tube.
Next, remove the gravity tube “SLEEVE” by pulling it straight off
the tube.