19
1) Mix the sanitizer (2 ounces of Steera Sheen green label or
equivalent) into a clean pail containing one gallon of warm
water. This solution will make a 200 P.P.M. (parts per million)
concentration of chlorine sanitizing solution. Pour the solution
into the mix tank.
IMPORTANT: Do not exceed the formula recommended by the
sanitizer manufacturer as it will not add to its effectiveness.
2) Pull the gravity feed tube out of the mix tank hole and lay it
down in the tank. This will allow the cylinder to completely
fill with the sanitizing solution.
3) Push selector button 571.2 to select the BEATER position.
Let the machine run for 30 seconds.
4) Push selector button 571.1 to turn “OFF” the machine.
5) Using a sanitized soft bristle brush, brush the sides of the mix
tank, and all other product contact areas. Allow the sanitizing
solution to remain in contact with all product contact areas for
three to five minutes.
6) Place the clean, sanitized pail under the dispensing head and
open the handles by pulling them in a downward direction.
571.1
571.2