21
Part VI – Starting the Freezer
Only after completing the cleaning and sanitizing
procedures should you fill the machine with fresh
mix. The mix being used
MUST
be free of ice,
seeds, pulp, and completely dissolved if made from
powder. The products used in these freezers must
be a homogenous liquid.
A) Gravity Fed Machine
With your clean, sanitized hands, remove the splash
guard and outer regulating sleeve from the gravity
feed tubes. Install only the center feed tube into the
cylinder feed hole. Reinstall the splash guard on
both tubes
Fill each mix tank with fresh liquid mix. Each mix
tank has a maximum capacity of 18 quarts. The
minimum recommended mix quantity is 6 quarts.
Allow the cylinders to fill with mix. When the air
bubbles stop coming out of the gravity feed tube,
the mix has filled the cylinder to its maximum
capacity. Remove the splash guard and install the
outer regulating sleeve onto the gravity feed tube.
Set to the closed position (bottom) and replace the
splash guard.
You may now start the freezing process by pressing
the “Select” button (#571.2) and selecting the
Automatic mode.
The initial freeze time is approximately 4-7
minutes. Do not dispense product until the machine
has cycled off. Before dispensing product you must
also open the outer regulating sleeve on the feed
tube. The draw rate, portion size, and mix viscosity
will determine the final regulating sleeve setting.
Our standard setting is 2 or 3 notches up from the
bottom. Adjust for your specific application.
571.2