Troubleshooting Chiller Start
Most common issue with the first start is air
leak shown by error code E3 - if E3
continues to flash for more than 30 seconds
than you will need to troubleshoot the
red
line
by doing the following:
1. Ensure washers have been used
between every connection.
2. Ensure clear filter housing is tightly
screwed on
3. Disconnect hoses; connect to check if
washers are in place - Over tightening
causes washer to be misplaced resulting in
air leaks.
4. Maybe sight tightening is required -
approach with caution.
5. Make sure water valve is in open
position ->
6. Reinstall filter making sure that two
rubber seals are in place on filter housing.
7. If issue persists please book a video
support call and we will troubleshoot the
issue live with you.