All connections to the batteries, solar panels and turbines are made to the six terminals on the bottom of the unit. If you will be using a wind turbine, you will need to connect your diversion 
load to the two terminals on the left-hand side of the unit. This unit may be used for wind (or hydro) only, solar only or both simultaneously. Multiple solar panels and or wind turbines 
may be hooked up as long as you do not exceed the total capacity of the unit.
  More information on these subjects is provided at http://ColemanAir.us (See: Articles and Information.) 

 

Ensure you have selected adequate sized wire for the amperage you will be controlling.  

Undersized wire can result in very high heat in the wire and connections possibly leading 

to a fire.    Always use a fuse or DC disconnect! Hooking up an energy source or diversion load without a fuse or disconnect can result in serious injury or death! 
 

This breakers inside the unit do not disconnect the unit from the battery bank power.  The external breaker shown above is required! 

 

Use extreme caution when installing or servicing this controller. High amperages and voltages can KILL you. – Always disconnect the controller before servicing. 