Follow these processes shown below to verify if your Coleman Wind Turbine is working
correctly.
Spin rotor shaft slowly with your fingers while at the same time touching the Wind turbines
positive and negative wires. With the wires touching the rotor shaft should become more
difficult to rotate. With the wires disconnected, it should spin freely. This creates a short.
Connecting the wind turbine’s wires (RED= Positive, BLACK = Negative) directly to the
corresponding posts of the battery ‘blinks’ the red LED four times. This will show the turbines
internal controller is operating correctly.
Should you not see the above mentioned indicators please contact your Sunforce Dealer.
I N S TA L L AT I O N
Choose a calm day and have someone available to help during the entire installation
process.
Caution: THE BLADE EDGES ARE SHARP. PLEASE HANDLE CAREFULLY.
Caution: Do not install the blade assembly until the body is mounted on the tower.
Caution: A L L B AT T E R I E S M U S T BE D I S C O N N E C T E D T H R O U G H O U T T H E
ENTIRE
I N S TA L L AT I O N P R O C E S S !
Please review the following wire gauge table to install the correct wire gauge. Coleman
recommends these as the minimum wire sizes for optimal performance.
Always use the largest gauge wires that are practical and affordable. Local, state, and or
national electrical codes take precedence over these general recommendations.
Caution: The use of undersized wire will result in loss of performance and potential
damage to your Coleman Wind Turbine and battery bank.
# Turbines 0 – 30ft
30ft – 60ft 60ft – 90ft
90ft – 150ft
150ft – 190ft
190 ft – 250ft
1
8g/8
6g/13
4g/21
2g/34
1g/53
0g/53
2
6g/13
4g/21
1g/44
00g/67
000g/85
0000g/107
3
4g/21
2g/34
0g/53
000g/85
0000g/107
Units given in AWG/
mm
²
Run your chosen wire through the pipe and drag the wires close to the batteries (Do not
connect to the battery at this point), strip the insulation back from each set of wires