background image

 

 

SAFETY GUIDELINES 

 

This manual contains information that relates to

 

PROTECTING YOUR SAFETY

 

and 

PREVENTING EQUIPMENT 

PROBLEMS

 and is very important for you to know and understand. We use the symbols below to help you 

recognize this information. 

 

DANGER

 - 

POTENTIAL HAZARD THAT WILL RESULT IN SERIOUS INJURY OR LOSS OF LIFE

 

 

WARNING

 - 

POTENTIAL HAZARD THAT COULD RESULT IN SERIOUS INJURY OR LOSS OF LIFE

 

 

CAUTION

 - 

POTENTIAL HAZARD THAT MAY RESULT IN MODERATE INJURY OR DAMAGE TO EQUIPMENT 

 

 

WARNING

 

 

 

1. 

RISK OF EXPLOSION OR FIRE.

 

Never spray flammable liquids in a confined area. It is normal for 

the motor and pressure switch to produce sparks while operating. If sparks come into contact with 
vapors from gasoline or other solvents, they may ignite and cause a fire or explosion. DO NOT 
smoke while spraying. DO NOT spray where sparks or flame are present. Keep compressor as far 
from spray area as possible. Always operate the compressor in a well-ventilated area. 

 
2. 

RISK OF ELECTRIC SHOCK.

 A licensed electrician in accordance with all local and national codes 

must install all wiring. To avoid electric shock, NEVER use an electric air compressor outdoor. when 
it is raining or on a wet surface.     

 

3. 

RISK OF BURSTING. 

Rust can weaken the tank.Drain the condensed water from the tank after 

each use to reduce rusting. DO NOT weld, drill or modify the air tank of this compressor.Welding or 
modifications on the air tank can severely impair tank strength and cause an extremely hazardous 
condition. If a leak detected in the tank, replace the tank right away. 

 

4. 

RISK OF INJURY. 

ALWAYS shut off the compressor, remove the plug from the outlet and bleed all 

pressure from the system before servicing the compressor or when the compressor is not in use. 
DO NOT use the unit with the shrouds removed. Contact with moving parts could cause serious 
injury.   

 

5. 

RISK OF BURSTING. 

Check the maximum pressure rating in the manual or the serial tag label. 

Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating. 
Relieve all pressure through the hose before removing or attaching accessories. 

 

6. 

RISK OF BURSTING. 

DO NOT adjust the pressure switch or relief valve for any reason. They have 

been preset at the factory for the maximum pressure of this unit. If the pressure switch or the relief 
valve are tampered with, personal injury or property damage may occur. 

 

7. 

RISK OF BURNS. 

Pump and manifold generate high temperature. To avoid burns or other injuries, 

DO NOT touch the pump, manifold or transfer tube while the unit is running. Allow the parts to cool 
before handling or servicing. Keep children away from the compressor at all times.   

 

8. 

RISK TO BREATHING. 

Read all labels when you are spraying paints or toxic materials, and follow 

the safety instructions. Use a respirator

 

mask if there is a chance of inhaling anything you are 

spraying.    NEVER directly inhale the compressed air produced by a compressor. 

 

9. 

RISK OF EYE INJURY. 

ALWAYS wear ANSI Z87.1 approved safety goggles when using an air 

compressor. NEVER point nozzle or sprayer toward a person or any part of the body. If the spray 
penetrates the skin, serious injury may occur.     

 

 

CAUTIO

N

 

 

1.  Pull the pressure relief valve ring daily to ensure that the valve is functioning properly. 
2.  The unit must be kept a minimum of 12 inches from the nearest wall, in a well-ventilated area for 

cooling. 

3.  Protect the air hose and electric cord from damage and puncture. Inspect them weekly for weak or 

worn spots and replace if necessary. 

4.  Always wear hearing protection when using an air compressor. Failure to do so may result in 

hearing loss. 

5.  Operation of the unit should always be in a position that is stable. Never use the unit on an elevated 

position that could allow the unit to fall or be tipped over.   

- 3- 

 

 

 

 

 

 

Summary of Contents for CM01213-15

Page 1: ...Industry Ltd Group All Rights Reserved Coleman R and are registered trademarks of The Coleman Company Inc used under license 2010 The Coleman Company Inc 15GAL AIR COMPRESSOR 3 5HP 15 GALLON IMPORTANT...

Page 2: ...LESHOOTING CHART 9 PARTS DRAWING PRATS LIST 10 WARRANTY 11 SPECIFICATION ITEM NO CM 01213 15 PUMP OIL LUBE DIRECT DRIVE MOTOR 2 5 Continuous HP VOLTAGE AMPS PHASE 120 15 1 AIR TANK CAPACITY 15 GALLON...

Page 3: ...ntact with moving parts could cause serious injury 5 RISK OF BURSTING Check the maximum pressure rating in the manual or the serial tag label Compressor outlet pressure must be regulated so as to neve...

Page 4: ...G J 4 A ELECTRIC MOTOR B AIR COMPRESSOR PUMP C PRESSURE SWITCH D PRESSURE RELIEF VALVE E AIR PRESSURE REGULATOR F TANK PRESSURE GAUGE G REGULATED PRESSURE GAUGE H AIR LINE OUTLET I AIR TANK DRAIN VALV...

Page 5: ...essure WARNING Never exceed the maximum working pressure of the tool F TANK PRESSURE GAUGE The gauge is used to measure the stored air pressure level of the tank It is not adjustable by the operator a...

Page 6: ...ressor according to the following guidelines a Set the compressor in a position near a grounded electrical outlet b The compressor must be at least 12 inches away from any wall or obstruction and in a...

Page 7: ...e tank drain valve Turn clockwise 8 Turn the pressure switch to the ON position The unit will start and fill the tank to the cut out pressure and stop NOTE The pressure switch will restart the motor a...

Page 8: ...y and to clear the valve of any possible obstructions Daily Clean the air filter A dirty filter will reduce the unit s performance and life To avoid any contamination of the inside pump the filter sho...

Page 9: ...e the pressure switch to the OFF position If the motor does not shut off unplug the air compressor If the electrical contacts are welded together replace the pressure switch Air compressor not large e...

Page 10: ...Filter 9 1 Oil fill plug 10 1 Pump Motor Assembly 11 1 Elbow 12 1 Shroud 13 2 Washer 14 2 Screw 15 1 Power cord ITEM QTY DESCRIPTION 16 2 Screw 17 4 Bolt 18 4 Washer 19 4 Spring washer 20 4 Nut 21 1...

Page 11: ...f you feel you have a defective product please submit a copy of your receipt to the address below and call 1 855 900 2653 for instructions prior returning this item to the store or sending back to Gre...

Reviews: