036-21603-002 Rev. A (1004)

Unitary Products Group

5

NOTES

1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m

3

/min).

2. Return air is through side opposite motor (left side).

3. Motor voltage at 115 V.

* Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2).

TABLE 2: Blower Performance CFM - Upflow (without filter) - Left Side Return

MODELS

Input / 

CFM

Speed

Two Stage Left Side Airflow Data (SCFM)

Ext. Static Pressure (in. H2O) 

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 

(F,L)C8T060A12UH11

High 

1770 1690 1630 1560 1490 1390 1290 1190 1050  920 

Medium 

High  1400 1380 1350 1320 1280 1230 1160 1060  930  780 

Medium 

Low  1120 1130 1150 1130 1120 1080 1000  950  790  630 

Low 

880 900 900 900 880 850 790 730 660 530 

(F,L)C8T080A12UH11

High 

1790 1720 1670 1590 1530 1450 1350 1260 1140 1000 

Medium 

High  1420 1370 1350 1320 1280 1230 1170 1090  990  840 

Medium 

Low  1080 1120 1110 1100 1080 1040 1000  920  820  690 

(F,L)C8T080B16UH11

Low 

N/A 900 900 890 870 850 800 730 670 560 

High 

2000 1960 1930 1900 1800 1760 1710 1640 1550 1460 

Medium 

1440 1440 1430 1420 1400 1380 1340 1300 1220 1150 

Low 

1220 1230 1230 1230 1200 1190 1170 1160  1110 1050 

FC8T100B12UH11

High 

1780 1710 1640 1560 1490 1390 1290 1180 1030  820 

Medium 

High  1430 1410 1370 1340 1280 1220 1140 1040  890  730 

Medium 

Low  1140 1170 1150 1120 1080 1040  970  890  760  630 

Low 

920 940 950 940 920 890 850 770 660 560 

(F,L)C8T100C20UH11

High 

2770 2670 2610 2540 2450 2340 2210 2070 1890 1730 

Medium 

High  2120 2060 2030 2000 1950 1880 1810 1720 1580 1370 

Medium 

Low  1690 1660 1630 1610 1560 1490 1420 1350 1240 1070 

Low 

1390 1370 1330 1290 1250 1200 1120 1010  910  850 

FC8T120C16UH11

High 

2160 2070 1990 1900 1800 1690 1580 1430 1260 1000 

Medium 

1760 1720 1690 1630 1560 1480 1390 1250 1080  890 

Low 

1510 1490 1470 1440 1380 1300 1210 1110  950  780 

FC8T120C16UH11

High 

2740 2650 2560 2480 2380 2280 2170 1990 1840 1650 

Medium 

High  2120 2090 2040 2000 1940 1870 1780 1680 1550 1370 

Medium 

Low  1690 1670 1650 1610 1560 1510 1440 1310 1160 1030 

Low 

1390 1360 1330 1300 1250 1190 1100 1020  940  840 

Field Wiring for Single Stage Thermostat

BLK

WHT

GRN

BLK (HOT)

WHT (NEUTRAL)

GRN

NOMINAL
120 VOLT

Y

W1

R

G

C

Y1

Y2

Y

W1

W

W2

R

G

C

SINGLE STAGE
THERMOSTAT

T’STAT
COMMON
CONNECTION

Field Wiring for Two Stage Thermostat

Y1

Y2

W1

W2

R

G

C

X/L

Y1

Y2

R

C

X/L

INTEGRATED
CONTROL

T’STAT
COMMON
CONNECTION

TWO-STAGE
THERMOSTAT

OUTDOOR
UNIT

Summary of Contents for Echelon FC8T

Page 1: ... year heat exchanger warranty on commercial applica tions 5 year limited parts warranty FEATURES Two stage heating operation includes Two stage gas valve Two stage inducer operation Provides increased comfort level very quiet unit oper ation Adjustable delay timer allows two stage operation with single stage thermostat Compact easy to install ideal height 40 cabinet Blower off delay for cooling SE...

Page 2: ...1 8 10 1 8 F L C8T080B16UH11 64 48 1600 B 17 1 2 16 1 4 13 1 8 11 5 8 FC8T100B12UH11 80 53 1200 B 17 1 2 16 1 4 13 1 8 11 5 8 F L C8T100C20UH11 80 53 2000 C 21 19 3 4 16 5 8 13 3 8 FC8T120C16UH11 96 64 1600 C 21 19 3 4 16 5 8 13 3 8 F L C8T120C20UH11 96 64 2000 C 21 19 3 4 16 5 8 13 3 8 HORIZONTAL VENTING MUST USE FIELDS CONTROL MODELS SWG 4Y OR TJERENLAND MODEL GPAK JT FIELD SUPPLIED POWER VENTIN...

Page 3: ...14 1 2 80 0 25 55 165 F L C8T080A12UH11 64 48 1200 14 1 2 80 0 30 60 175 F L C8T080B16UH11 64 48 1600 17 1 2 80 0 25 55 160 FC8T100B12UH11 80 53 1200 17 1 2 80 0 25 55 170 F L C8T100C20UH11 80 53 2000 21 80 0 25 55 160 FC8T120C16UH11 96 64 1600 21 80 0 25 55 180 F L C8T120C20UH11 96 64 2000 21 80 0 25 55 170 Model Output Blower Blower Size Total Unit Max Over current Size awg 75 ft protect Min Wir...

Page 4: ...0 F L C8T080B16UH11 High 1850 1820 1790 1750 1690 1630 1570 1500 1430 1330 Medium 1470 1450 1440 1430 1390 1360 1310 1270 1220 1150 Low 1260 1260 1260 1260 1250 1200 1150 1110 1070 1010 FC8T100B12UH11 High 1700 1620 1560 1480 1390 1300 1210 1110 970 820 Medium High 1430 1400 1350 1300 1230 1160 1080 980 870 710 Medium Low 1180 1170 1160 1130 1080 1030 1000 860 750 510 Low 950 950 930 920 880 840 7...

Page 5: ...0 Low 1220 1230 1230 1230 1200 1190 1170 1160 1110 1050 FC8T100B12UH11 High 1780 1710 1640 1560 1490 1390 1290 1180 1030 820 Medium High 1430 1410 1370 1340 1280 1220 1140 1040 890 730 Medium Low 1140 1170 1150 1120 1080 1040 970 890 760 630 Low 920 940 950 940 920 890 850 770 660 560 F L C8T100C20UH11 High 2770 2670 2610 2540 2450 2340 2210 2070 1890 1730 Medium High 2120 2060 2030 2000 1950 1880...

Page 6: ...hat total system static is 0 58 w c To determine the system airflow complete the following steps Obtain the airflow values at 0 50 w c 125 Pa 0 60 w c 150 Pa ESP Airflow 0 50 2125 CFM 60 17 m3 min Airflow 0 60 2035 CFM 57 62 m3 min Subtract the airflow 0 50 w c 125 Pa from the airflow 0 60 w c 150 Pa to obtain airflow difference 2035 2125 90 CFM 2 55 m3 min Subtract the total system static from 0 ...

Page 7: ...WITCHES Used to convert units for operation at altitudes from 4 500 ft to 10 000 ft Input MBH Output MBH 2 000 Ft to 5 500 Ft 5 500 Ft to 0 000 Ft 40 32 1PS0301 1PS0301 60 48 1PS0301 1PS0301 80 64 1PS0302 1PS0302 100 80 1PS0312 1PS0311 115 92 1PS0312 1PS0311 130 104 1PS0312 1PS0311 FIELD INSTALLED ACCESSORIES ELECTRICAL MODEL NO DESCRIPTION USED WITH 2ET0770010124 THERMOSTAT Two stage Heat Cool de...

Page 8: ...e without notice Printed in U S A 036 21603 002 Rev A 1004 Copyright by York International Corp 2004 All rights reserved Supersedes 036 21603 001 Rev B 0904 Unitary 5005 Norman Products York OK Group Drive 73069 NOTES ...

Reviews: