Coleman Roto Mold Spa (online sales)
LTR50001136, Rev. A
Pr
eparing f
or
Your Ne
w P
or
tab
le Spa
7
High Power Configuration
OFF Position (Down)
Default
setting
ON Position (Up)
Test Mode OFF
A1
Test mode (normally OFF)
Button layout will be: Unused,
Pump 1, Temp, Light
A2
Button layout will be: Pump 1,
Light, Temp Down, Temp UP
Use Lite Duplex or Digital
Duplex panel
A3
Use Mini Panel
N/A (must be OFF)
A4
Pump 1 high-speed timeout
See table below
A5
60Hz operation
A6
50Hz operation
Standard/Economy/Sleep
mode changes allowed
A7
Standard mode only
Temperature displayed in
Fahrenheit
A8
Temperature displayed in
Celsius
Pump 1 low-speed timeout
See table below
A9
Heater can run while the high-
speed pump is running (HIGH
amperage mode)
A10
Heater is disabled while the
high-speed pump is running
(LOW amperage mode)
Note: Arrow indicates factory default setting.
Pump 1 Timeouts
A5
A9
Low speed High speed
OFF
OFF
2 hours
15 minutes
ON
OFF
2 hours
30 minutes
OFF
ON
15 minutes
15 minutes
ON
ON
30 minutes
30 minutes