background image

363658-CTG-G-0613

Johnson Controls Unitary Products

5

1. Airflow expressed in standard cubic feet per minute (CFM).
2. Motor voltage at 115 V.

Blower Performance CFM - Any Position  (without filter) - Bottom Return

Models

Speed

Bottom Airflow Data (SCFM)

Ext. Static Pressure (in. H2O)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

TG(8,L)S040A08MP11

High 

966 923 874 804 717 566 386 121  NA  NA 

Medium 

High  813 782 743 687 605 464 280 118  NA  NA 

Medium 

Low  745 706 667 619 545 413 205  NA  NA  NA 

Low 

684 655 614 565 489 342 171  NA  NA  NA 

TG(8,L)S060A10MP11

High 

1292 

1230 

1160 

1088 

1004 891 760 476 129 129 

Medium 

High 1203 

1157 

1105 

1035 942 846 728 485 133 129 

Medium 

Low 1043 

1010 962 905 823 705 491 305 124 123 

Low 

869 845 811 772 708 579 438 178 145 125 

TG(8,L)S060A12MP11

High 

1358 1341 1319 1303 1275 1238 1190 1130 1062  943 

Medium 

High  1097 1083 1075 1064 1042 1024  997  962  906  821 

Medium 

Low  935 928 920 899 872 840 809 771 731 659 

Low 

800 779 763 736 711 687 657 622 584 529 

TG(8,L)S080B12MP11

High 

1329 1307 1285 1247 1195 1143 1091 1027  927  806 

Medium 

High  994 1004 

1008 984 970 941 893 839 773 669 

Medium 

Low  786 790 782 781 761 743 726 685 630 540 

Low 

655 654 647 629 620 594 560 524 469 399 

TG(8,L)S080C16MP11

High 

1881 1822 1783 1696 1602 1539 1465 1394 1267 1130 

Medium 

High  1553 1535 1492 1456 1408 1343 1279 1226 1113 1014 

Medium 

Low  1312 1286 1288 1260 1205 1143 1091 1029  966  841 

Low 

1169 

1166 

1128 

1098 

1069 

1032 987 909 835 747 

TG(8,L)S080C22MP11

High 

2811 2725 2638 2540 2448 2339 2224 2111 1974 1831 

Medium 

High  2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 

Medium 

Low  1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 

Low 

1396 1375 1348 1325 1263 1200 1150 1120 1052  965 

TG(8,L)S100B12MP11

High 

1314 1318 1292 1265 1223 1177  1119 1051  971  890 

Medium 

High 1010 

1004 

1003 995 992 956 914 857 798 721 

Medium 

Low  812 805 796 786 777 754 727 685 626 560 

Low 

661 659 644 623 614 605 568 532 482 399 

TG(8,L)S100C16MP11

High 

2069 2014 1956 1885 1820 1748 1668 1577 1468 1362 

Medium 

High  1662 1656 1639 1608 1586 1544 1491 1421 1338 1204 

Medium 

1368 1371 1377 1376 1367 1334 1295 1250 1188 1104 

Low 

1016 1014 1018 1030 1012  996  975  944  898  852 

TG(8,L)S100C20MP11

High 

2893 2774 2687 2589 2478 2376 2255 2120 1978 1824 

Medium 

High  2272 2243 2204 2169 2086 2018 1940 1842 1743 1602 

Medium 

Low  1765 1752 1737 1718 1674 1619 1561 1493 1437 1312 

Low 

1425 1380 1409 1378 1307 1274 1226 1180  1113 1025 

TG(8,L)S120C16MP11

High 

1752 1724 1702 1664 1600 1542 1454 1372 1264 1119 

Medium 

High  1469 1449 1453 1420 1382 1344 1269 1197  1118 1022 

Medium 

Low  1248 1235 1226 1207 1179 1133 1077  992  922  841 

Low 

1076 1076 1046 1025 1002  968  927  869  784  707 

TG(8,L)S120C20MP11

High 

2701 2620 2533 2429 2338 2227 2112 1993 1861 1706 

Medium 

High  2125 2083 2046 1994 1955 1901 1857 1737 1621 1497 

Medium 

Low  1664 1664 1647 1619 1580 1555 1468 1392 1332 1226 

Low 

1358 1339 1330 1318 1286 1235 1185 1141 1060  938 

TG(8,L)S130D20MP11

High 

2823 2714 2613 2507 2399 2282 2170 2042 1908 1761 

Medium 

High  2242 2188 2154 2102 2045 1970 1887 1792 1673 1537 

Medium 

Low  1805 1791 1738 1725 1675 1623 1567 1487 1394 1256 

Low 

1425 1427 1403 1335 1324 1280 1236 1176 1103  996 

Summary of Contents for TG8S

Page 1: ...ional Fuel Gas Code FEATURES Easily applied in upflow horizontal left or right or downflow installation with minimal conversion necessary Compact easy to install ideal height 33 tall cabinet Blower off delay for cooling SEER improvement Easy access to controls to connect power control wiring Built in high level self diagnostics with fault code displays standard on integrated control module for rel...

Page 2: ... 8 L S100B12MP11 1200 B 17 1 2 16 3 8 11 8 108 TG 8 L S100C16MP11 1600 C 21 19 7 8 13 6 118 TG 8 L S100C20MP11 2000 C 21 19 7 8 13 6 122 TG 8 L S120C16MP11 1600 C 21 19 7 8 15 8 123 TG 8 L S120C20MP11 2000 C 21 19 7 8 15 8 129 TG 8 L S130D20MP11 2000 D 24 1 2 23 3 8 17 5 135 Ratings Physical Electrical Data Models Input Output AFUE Air Temp Rise Max Outlet Air Temp Blower Blower Size Max Over Curr...

Page 3: ...e return with a transition to allow use of a 20x25 filter Single side return above 1800 CFM is approved as long as the filter velocity does not exceed filter manufacturer s rec ommendation and a transition is used to allow use on a 20x25 filter NOTICE Recommended Filter Sizes CFM Cabinet Size Side in Bottom in 800 A 16 x 25 14 x 25 1000 A 16 x 25 14 x 25 1200 A 16 x 25 14 x 25 1200 B 16 x 25 16 x ...

Page 4: ... 1CK0603 1CK0604 Combustible Floor Base Kit For installation of these fur naces in downflow applications directly onto combustible floor ing material These kits are required to prevent potential overheating situations These kits are also required in any appli cations where the furnace in installed in a downflow configura tion without an evaporator coil where the combustible floor base kit provides...

Page 5: ...0 2448 2339 2224 2111 1974 1831 Medium High 2234 2233 2147 2092 2042 1974 1907 1820 1705 1575 Medium Low 1722 1716 1690 1681 1603 1553 1489 1426 1335 1241 Low 1396 1375 1348 1325 1263 1200 1150 1120 1052 965 TG 8 L S100B12MP11 High 1314 1318 1292 1265 1223 1177 1119 1051 971 890 Medium High 1010 1004 1003 995 992 956 914 857 798 721 Medium Low 812 805 796 786 777 754 727 685 626 560 Low 661 659 64...

Page 6: ...1035 Medium 1294 1297 1271 1238 1187 1120 1083 1028 979 851 Low 1126 1115 1095 1049 1027 996 957 929 840 742 TG 8 L S080C22MP11 High 2972 2863 2769 2671 2571 2465 2352 2227 2095 1950 Medium High 2173 2146 2103 2082 2036 1966 1904 1827 1738 1621 Medium Low 1670 1667 1647 1618 1585 1549 1492 1408 1350 1238 Low 1371 1339 1317 1284 1259 1199 1147 1085 1024 928 TG 8 L S100B12MP11 High 1258 1278 1283 12...