Conne buildup [electronic]
64
8.3.4 Connection „Applicator PE“
PE Connection(s)
[all applicator types]
This PE connection is identical for all applicator boards:
The PE screw terminal below the applicator board will be used to
connect:
the PE cable from the dispensing edge
the PE cable from the main board (X4) - or
the PE wire - from the AC-OUT terminal X2-3 via magnet-
flap applicator power cable (if a magnet flap applicator is
mounted).
8.3.5 Label scanner (explanation)
Label sensor
Sender-part
[all standard applicator-versions]
The sender part of the label scanner is mounted inside of the peel
off plate. The sender part is composed of:
Sender print
Light tube
Label sensor
Receiver-part
[all standard applicator-versions]
The label scanner receiver part is placed in a small round housing.
The so called receiver head is placed on top of the sender light
tube and can be easily moved across the label. Also the distance
between light tube and receiver head can be adjusted (booklets.
The sensor cables are special cables and should not be replaced
with others.
8.3.6 Cable inputs/outputs
Cable inputs/outputs
[all applicator-versions]
All cables/wires „not“ going through the modular rail (backside) to
the applicator are guided through the cable input/output clamps
(bottom of the traction unit and applicator).
Special case
C4300-BUDGET:
the label scanner for this type of
labeler will be connected directly to the main terminals on the main
board (bottom). The label scanner cables are guided through the
modular rail to the main board (entry of modular rail).