6.10 Control signals for external units
The signals FEED and READY are used to control external units.
6.10.1 FEED
The FEED signal indicates that the labeler is dispensing. This means that the steppermotor is
turning. With this signal an external flat printing unit can be controlled. See therefore figure 20.
6.10.2 READY
The signal READY is used to signal the Collamat that a connected peripheral device like hot-
stamp or flatprinter is ready. If the signal is active, this means the NPN-output of the device is
pulled to GND, labelling is not possible. An error message is then displayed.
Figure 20: Timediagram of the GSC, LSC and FEED signal
1. Speed dependent position delay
2. Length of the predispensing
All signals are Open-Collector to ground and capable to drive a maximum load of 100 mA. See
figure 25.
GSC2
Clock
FEED
LSC
t
Signal
1
2
5999.545-01G 28.02.2006 WM
Page 27 / 65
Summary of Contents for Etiprint Inline
Page 65: ...Etiprint Inline Manufacturer s declaration Register A Manufacturer s declaration...
Page 66: ...Etiprint Inline Manufacturer s declaration 66...
Page 68: ...Etiprint Inline Manufacturer s declaration 68...
Page 69: ...Etiprint Inline Replacement parts Wear parts Register B Replacement parts Wear parts...
Page 70: ...Etiprint Inline Replacement parts Wear parts 70...
Page 74: ...Etiprint Inline Replacement parts Wear parts 74 Draw mechanism spare parts cont...
Page 78: ...Etiprint Inline Electric circuit drawing with printer type SATO...
Page 79: ......
Page 80: ......
Page 82: ...Etiprint Inline Electric circuit drawing with printer type ZEBRA...
Page 84: ......
Page 86: ...Etiprint Inline Collamat 8600 9100 Monitor Operating instructions...
Page 87: ...Collamat 8600 9100 Operating instructions Monitor 5999 530 01F...
Page 144: ...Etiprint Inline Collamat 8600 9100 Monitor Technical Manual...
Page 145: ...Collamat 8600 Technical handbook 5999 545 01G...
Page 188: ......