Shaker
V
IBA
15
&
V
IBA
25
Collomix Rühr- und Mischgeräte GmbH
D-85080
Gaimersheim
22
Edition
2.3-05
7.4.7
Setting the high clamping pressure
(DC-MOT CLAMP HIGH)
The value set with DC-MOT CLAMP HIGH is used to clamp containers which are bigger
than the value set under SMALL POT HEIGHT.
Works setting 390 kg.
For details of how to set the correct clamping pressure see 7.4.6
DC-MOT CLAMP HIGH 3
CLS 75 OPEN EDIT
•
•
Change the high clamping pressure
Button I (CLS):
close the mixing unit
Button II
(OPEN): open the mixing unit
Button III
(EDIT): edit the parameter
•
DC-MOT CLAMP HIGH 3
+ 80 -
•
•
Edit the parameter and use a pressure cell to
check the clamping pressure
Button I ( + ):
increase the value
Button II ( - ):
decrease the value
•
•
DC-MOT CLAMP HIGH 3
+ 80 -
•
•
Press button "E" to return to the main menu
•
DC-MOT CLAMP HIGH 3
CLS 80 OPEN EDIT
•
•
DC-MOT CLAMP HIGH 80
Pot clamped 80
•
The mixing unit is closed and the loaded
container (pot) is clamped.
•
SHAKER MOT OFF
ON OFF
•