Shaker
V
IBA
15
&
V
IBA
25
Collomix Rühr- und Mischgeräte GmbH
D-85080
Gaimersheim
24
Edition
2.3-05
7.4.10
Deactivating the service menu
•
Switch off the machine with the main switch
•
Move jumper ST8 on the control pcb to OPERATION
•
Flip up the control panel and screw in place
•
Fit the control panel cover (POS 10.119)
•
Switch on the machine with the main switch
•
The self-test routine follows after switch-on
•
Display of the software version
Collomix VIBA init..
Version X.XX
•
d: 40
c: 80 / 25 : 220
•
Display of:
d = DC-MOT ENDPOS
c = CLAMP HIGH / LOW : SMALL POT HEIGHT
•
•
Display of mixing cycles performed so far
Collomix VIBA init..
000011 cycles
•
•
Basic display when no faults are active. The
mixing cycle can be started.
Ready
1:00 2:00 3:00
The changes were correctly saved and adopted when the edited parameters are
displayed during initialization.
Control panel flipped
down
Control panel closed
ST8 connector on the control pcb
SERVICE
OPERATIO
N