background image

 

 

Owner’

s Manual 

HH0308C Auto-Ranging DC/True RMS AC Digital Multimeter 
 
1, DESCRIPTION 
    Thanks for choosing our product as your reliable tool. 
    The HH0308C auto-ranging digital multimeter is designed for measuring resistance, capacitance,        

DC/True RMS AC voltage, DC/True RMS AC current, frequency, duty cycle and temperature, 
testing diodes, transistors and checking continuity. 

This meter is designed for indoor use at altitude up to 2000m, temperature between 5  and 

    40 , the maximum humidity 80% for temperature up to 31º C decreasing linearly to 50% relative  

humidity at 40º C and pollution degree 2. 

    The LCD display is clear and easy to read. The functions of auto-range, auto power shut-off,  
    over-range protection and low battery indication provide you the maximum convenience.     
 
2, SAFETY INSTRUCTIONS 
 

This meter has been designed for safe use, complying with IEC61010.1 CAT II 1000V DC, but 
must be operated with caution. The rules listed below should be carefully followed for safe use. 

2.1 NEVER operate this device when the back cover is open or not properly attached in its place. 
2.2 Make sure that the insulation of leads is not damaged. 
2.3 When BAT appears on the display, change both batteries to maintain accurate  measurement. 
2.4 NEVER apply voltage to the meter that exceeds the specified maximum: DC1000V or AC750V. 
2.5 USE extreme caution when working with voltage over the 36V safe point. 
2.6 NEVER change the position of the function switch during measuring. 
2.7 CHOOSE the correct positions of all function switches before testing. 
2.8 NEVER change any connection on the circuit board of the meter. 
2.9 USE only damp cloth or mild detergent to clean the outside of the meter. 
2.10 Safety Symbols: 
 

 

 Hazardous 

voltage 

 

 

 

 

 

Read the manual first 

 

 

 

   

Connect to common ground 

 

 

            

                        This product is protected by DOUBLE INSULATION. Service of this meter should be   
                         performed by a professional person only. Otherwise the safety design of this meter  
                         could be compromised and severe injury or even death may result.   
 
3, SPECIFICATIONS 
 

 

3.1 GENERAL 
3.1.1  Display: LCD  
3.1.2  Maximum read: 5999 with auto polarity display (no sign for positive polarity).     
3.1.3  Measuring method: A/D converter 
3.1.4  Sampling speed: 3 times/sec. 
3.1.5  Maximum common mode voltage: 500V AC/DC 
3.1.6  Over range indication: Flashing number, audible signal sound or “OL” displayed 
3.1.7  Relative measurement indication: “ ”displayed. 
3.1.8  Auto shut-off switch: Meter will be shut off after 30 minute from last use. 
3.1.9  Low battery indication: “

” is displayed if battery voltage drops below operating voltage. 

3.1.10 Operating environment: 5-35

°

C, Humidity 

<

75%. 

3.1.11 Storing environment: -10 to 50

°

C, Humidity 

<

75%. 

3.1.12 Power supply: Two “AAA” 1.5V batteries. 
3.1.13 Size: 182mm X 88mm X 45mm. 
3.1.14 Weight: 347g. 
3.1.15 Fuse: 800mA/250V Fast, 15A/250V Fast. 
3.1.16 Accessories included: This manual, one set of test leads, a K type temperature probe and two 

AAA batteries. 

Summary of Contents for HH0308C

Page 1: ...PORTANT Read and understand this manual before using the tester Failure to understand and comply with safety rules and operating Instructions can result in serious or fatal injuries and or property da...

Page 2: ...orking with voltage over the 36V safe point 2 6 NEVER change the position of the function switch during measuring 2 7 CHOOSE the correct positions of all function switches before testing 2 8 NEVER cha...

Page 3: ...60uF 100uF 0 01nF 0 1nF 1nF 10nF 100nF 10 rdg 25dgts 2 5 rdg 10dgts The VAC and AAC ranges are specified from 5 to 100 of the range Input Impedance 10M AC DC measurement Diode Test reads approximate...

Page 4: ...voltage press this button once the value on the display will be changed from 5V to 0V Disconnect the test lead from the source 5V will be displayed on the LCD If you measure a 4 5VDC source the LCD w...

Page 5: ...it only changes the decimal point 3 Remove power from the circuit under test Then open up the circuit at the point where you wish to measure current 4 Touch the black test lead tips to the negative si...

Page 6: ...4 Touch the test probe tips across the diode under test read the value on the display 5 Reverse the test probes measuring positions across the diode and read the value 6 The result may as follow 6 1...

Page 7: ...above the jack V F CAP will shine 2 Insert the black test lead banana plug into the negative jack COM and the red test lead banana plug into the positive jack V F CAP 3 Press the HZ button twice the...

Page 8: ...d from any source of voltage 6 4 Remove the screw on the back of the meter then remove the back cover 6 5 Remove the old batteries and insert a pair of new and same type batteries in the right place 6...

Page 9: ......

Reviews: