3.2 SPECIFICATIONS
Function Range Resolution
Accuracy
DC Voltage
(V DC)
6V
60V
600V
1000V
1mV
10mV
100mV
1V
±(0.3% rdg + 3 dgts)
±(0.8% rdg + 3 dgts)
AC Voltage
(V AC)
6V
60V
600V
750V
1mV
10mV
100mV
1V
±(1% rdg + 8 dgts)
DC Current
(A DC)
600µA
6000µA
60mA
600mA
6A
20A
0.1µA
1µA
10µA
100µA
1mA
10mA
±(0.8% rdg + 5 dgts)
±(2% rdg +5 dgts)
AC Current
(A AC)
600µA
6000µA
60mA
600mA
6A
20A
0.1µA
1µA
10µA
100µA
1mA
10mA
±(1.2% rdg +8dgts)
±(2% rdg + 8 dgts)
Resistance
600
Ω
6k
Ω
60k
Ω
600k
Ω
6M
Ω
60M
Ω
0.1
Ω
1
Ω
10
Ω
100
Ω
1k
Ω
10k
Ω
±(0.5% rdg +5 dgts)
±(2% rdg + 10 dgts)
Frequency
(Auto Range)
11Hz to 600kHz
0.1Hz
1Hz
10Hz
100Hz
1kHz
±(0.1% rdg + 3 dgts)
Duty Cycle
0.1% 99.9%
0.1%
±(1.2% rdg + 2 dgts)
pulse width 100µs 100ms
TEMP
-20
300
1
±4
TEMP
-4°F 572°F
1
±6°F
Capacitance
(Auto Range)
60nF
600nF
6uF
60uF
100uF
0.01nF
0.1nF
1nF
10nF
100nF
±(10% rdg + 25dgts)
±(2.5% rdg + 10dgts)
The VAC and AAC ranges are specified from 5% to 100% of the range.
Input Impedance – 10M
Ω
(AC/DC measurement).
Diode Test – reads approximate forward voltage, test current of 1mA maximum.
Continuity Check – Audible signal will sound if the resistance is less than 40
Ω
±10
Ω
.
Transistor Test –reads approximate
h
FE
value of transistor under test.
Understand the AC zero input.
When measuring the AC voltage and current, the meter is calculating the input and converting it to
the data that the LCD can display. The converter needs a certain level of the input voltage to make
the measurement. This level is 5% of the ranges for this meter. So that, the non-zero digits that are
displayed on the meter (especially the True RMS meter) when the test leads are open or are
shorted are normal. This will not affect the specified AC accuracy above 5% of the ranges.
4. OPERATION
Summary of Contents for HH0308C
Page 9: ......