background image

GETTING STARTED

Color Kinetics® iW PDS-150 is a robust 150W power source and 

intelligent data drive circuitry specifically designed for use with Color 

Kinetics IntelliWhite Series fixtures.
This guide contains important information on installing and using 

your new iW PDS-150. Please read it carefully and save it for future 

reference.  There are few rules, but those that exist are there for your 

safety.
This power supply is not suited for outdoor locations and must be 

shielded from water spray.

INCLUDED IN THIS BOX

•  iW PDS-150 power supply/data circuit module

• 6 - Module-to-housing mounting screws and lock washers

• Housing

• Cover with 8 mounting screws

• Spare fuses

• Data terminator

• Installation Guide
• Warranty and Registration cards

ADDITIONAL ITEMS NEEDED

•  Mounting hardware

• Power screwdriver

• Small screwdriver

• Wire nuts

SCOPE OF THIS USER GUIDE

The goal of this user guide is to explain in an easily understood language 

the necessary steps to install the iW PDS-150 and assure peak perfor-

mance. Its intended use is for reference only, by persons who are fully 

qualified. This document should never be considered a substitute for any 

provisions of a regulation or state and/or local code.

Identification and Warnings of Safety Hazards

In accordance with ANSI MH29.1 the following system of identifying 

the severity of the hazards associated with the products is used:

DANGER

”  Imminently hazardous situation which, if not avoided, will 

result in death or serious injury.

WARNING

” Potentially hazardous situation that, if not avoided, could 

result in death or serious injury.

CAUTION

”  Potentially hazardous situation that, if not avoided, may 

result in minor or moderate injury or property damage.

DANGER

: Ensure that main power supply is off before installing, wir-

ing, or servicing the iW PDS-150 power supply.  Failure to adhere to 

these instructions will result in death or serious injury.

WARNING

iW PDS-150 is rated for installation in environments where 

the temperature does not exceed 122˚F (50˚C). To ensure product per-

formance, 4 inches of open space is required around all vented sides 

of the unit. Do not obstruct the vent holes on the housing cover.

WARNING

: The iW PDS-150 power supply must be installed by a qual-

ified professional in accordance with NEC and relevant local codes. 

Failure to comply can result in death, serious injury, or property dam-

age.

WARNING

: Do not attempt to install or use the iW PDS-150 until you 

read and understand the installation instructions and safety labels.  

Failure to adhere to these instructions could result in serious injury or 

property damage.

WARNING

: Do not use the iW PDS-150 if power cables are damaged.  

Doing so can result in death, serious injury, and property damage.

CAUTION

: Do not hot swap. Ensure the power supply is disconnected 

from line AC before connecting or disconnecting fixtures. Hot swap-

ping will result in property damage and void the warranty. 

CAUTION

: Ensure that there are 4 inches of open space on all vented 

sides of power supply. Failure to do so will result in property damage 

and void the warranty. 

CAUTION

: Do not use with dimmers. Doing so will result in property 

damage and void the warranty.

CAUTION

: Do not modify or alter the iW PDS-150. Doing so will void 

the warranty. 

NOTE

:

 

The instructions and precautions set forth in this user guide are 

not necessarily all-inclusive, all conceivable, or relevant to all applica-

tions as Color Kinetics cannot anticipate all conceivable or unique 

situations.

OWNER/USER RESPONSIBILITIES

It is the responsibility of the contractor, installer, purchaser, owner, 

and user to install, maintain, and operate the iW PDS-150 in such a 

manner as to comply with all state and local laws, ordinances, regula-

tions, and the American national Standard Institute Safety Code.

INSTALLING THE iW PDS-150

The iW PDS-150 shall be installed by a qualified electrician in 

accordance with NEC and relevant local codes for power supplies 

with Class 2 outputs. A power screwdriver is recommended for 

mounting the unit.

INSTALLATION CONSIDERATIONS

• Zones. iW PDS-150 uses Color Kinetics iW Scene Controller to 

control Color Kinetics IntelliWhite dimmable, color temperature 

adjustable fixtures by zones. A zone is a grouping of lights attached 

to an iW power/data supply which has been set to a specified 

zone designation. The zone designation of the iW power/data 

supply defines the zone in which the lights reside. Using the 

iW Scene Controller, you can set the brightness level and color 

temperature, from cool to warm, for all lights within specified zones. 

Zones are created by internally designating each iW PDS-150 as 

a specific alphanumeric zone, 1-9 or A-F. All fixtures attached to 

that iW PDS-150 reside within the designated zone. For example, 

in an installation with two iW PDS-150s where the first power/data 

supply is set to Zone 1 and the second is set to Zone 2, the lights 

attached to the first are in Zone 1 and the lights attached to the 

second iW PDS-150 are in Zone 2.
For installations where all lights are controlled in unison, set each 

power/data supply in the installation to the same zone designator. 

For installations where groups of lights are controlled individually, 

set unique zone designators for each power/data supply. 

•  Location of iW PDS-150 in relationship to lights. Refer to the 

user guide for your IntelliWhite fixture to determine the maximum 

distance from the fixture to install the iW PDS-150.  

NOTE

: Adhere to all state and local wiring codes when making the 

leader extension connections.

•  Maximum number of fixtures per iW PDS-150. Refer to the user 

guide for your IntelliWhite fixtures to determine the maximum 

number of fixtures per iW PDS-150 and the maximum number of 

fixtures per fuse group.

STEPS TO A SUCCESSFUL INSTALLATION

1. Set the zone(s) for the iW PDS-150s
2. Install the iW PDS-150.
3. Wire the iW PDS-150.
4. Connect the iW Scene Controller

SET THE iW POWER/DATA SUPPLY ZONE

To minimize installation time and effort, set the zone for each iW PDS-

150 prior to installing. Zones can be set or changed after installing 

the iW PDS-150; however, any settings or changes made after power 

is engaged requires a power cycle to recognize  

the change. 
Using a small, flat-head screw driver, set the zone for the iW PDS-150 

by rotating the zone switch, located Zone Net Out port, to a specific 

designator–1 to 9 or A to F. The designator zero (0) is reserved for 

future features. See Fig. 1.

INSTALL THE iW PDS-150

•  Select the location to mount the housing, keeping the iW PDS-150 

within the maximum distance specified for your fixture and control-

ler. Refer to user guides for the cable run information.

NOTE

Specifications for specific fixtures supersede this information. 

In certain conditions the maximum cable run is less than 60 feet.

•  Prior to mounting, punch out the appropriate number of pre-formed 

conduit holes. 

•  Mount the housing to a flat surface using four screws suitable for the 

mounting surface. Mounting holes are located at each corner of the 

bottom of the housing. (See mounting details, Fig. 1.)

MOUNTING THE POWER/DATA MODULE IN THE HOUSING

•  Mount the Power/Data module prior to pulling the wiring into the 

housing.

•  Mount the power/data module to the stand-off holes in the bottom 

of the housing using the provided mounting screws and lock wash-

ers. Mate the slotted hole of the board to the PEM mount referenced 

in Fig. 2. (Refer to Fig. 3 for correct orientation.)

WIRING THE iW PDS-150

After mounting the power/data module, you are ready to connect 

your IntelliWhite series fixtures.

CONNECTING INTELLIWHITE FIXTURES TO THE IW PDS-150

There are three fuse groups, each having two output terminals on the 

power supply.  Refer to the user guide for your IntelliWhite fixture for 

the maximum number of fixtures per fuse group allowed.

•  Connect the fixture cables to the output 

terminal connectors. 

• Ensure that the red, white and black 

wires correspond to the 3-pin terminal 

block notations (See Fig. 4.)

• Snap the terminal connector into the 

output terminal.

i

W  PDS-150

I N S T A L L A T I O N

 

G U I D E

Color Kinetics Incorporated
10 Milk Street, Suite 1100
Boston, MA 02108
Tel 888 Full RGB
Tel 617 423 9999
Fax 617 423 9998
info@colorkinetics.com
www.colorkinetics.com

ITEM# 509-000001-00

©2004 Color Kinetics Incorporated. All rights reserved. Chromacore, Color 

Kinetics, the Color Kinetics logo, ColorBlast, ColorBurst, ColorBlaze, ColorPlay, 

ColorScape, iColor, iColor Cove, iPlayer, Optibin, QuickPlay, and Smartjuice are 

registered trademarks, and Chromasic, ColorCast, IntelliWhite, and Powercore 

are trademarks of Color Kinetics Incorporated.
PUB-000124-00 Rev 00
Specifications subject to change withou notice.

MATE SLOTTED HOLE OF BOARD HERE

PEM MOUNTS FOR FOR POWER/DATA

MODULE, #8 MOUNTING SCREWS (PROVIDED)

1/4" HOUSING MOUNTING HOLES

8.58"

9.75"

Fig. 2

OPEN FRONT

CONDUIT

SIDE

VENTED

SIDE

POWER

SUPPLY

POWER/DATA

MODULE

Fig. 3

BLK

WHT

RED

COM

DATA

24V

Fig. 4

WARNING

: Make sure the power supply is off before connecting or 

disconnecting fixtures. Otherwise, damage to the fixture will result.

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

RED

WHT

BLK

CONTROLLER

ZONE NET

IN

ZONE NET

OUT

ZONE 

NUMBER

Output

Fault

Zone Net

Heart Beat

Power

ZONE 

NUMBER

OUT

Fig. 1

Reviews: