20
Treadmill Hardware Manual 1011-0002 v1.02
To access the User Menu:
Press and hold the RATE button.
Press and hold the MODE button.
Then press and release the ODOMETER RESET button.
Release the RATE and MODE buttons.
The screen will display:
USER MENU
, and then will position you in the menu at the option for automatic speed
and distance odometer calibration:
AutoCal Speed
.
The menu options are as follows:
•
Restore Defaults
•
Serial Number
•
Run-Time Meter
•
Odometer
•
Fan Voltage
•
Unit ID
•
Baud Rate
➢
AutoCal Speed
•
Accel
•
Mode
•
Calibrate Shock
•
Exit
The INTENSITY knob is used to navigate the options on the User Menu. Clockwise rotations will move the
selection arrow up, and counterclockwise rotations will move the arrow down.
Press the ODOMETER RESET button to select an option to edit and save any changes.
Use the SPEED knob to adjust the settings and values while editing.
3.1 Restore Defaults
The top option on the menu list. This is used to restore all
the factory settings saved during the treadmill’s
factory calibration. This may be necessary during service to restore a known configuration should for any
reason the current settings be unknown or have become corrupt and the treadmill system is non-responsive.
Press the ODOMETER RESET button to select this option. The screen will display:
Restore Defaults Are
You Sure?
Press and hold the ODOMETER RESET button to restore the factory settings, press and release to cancel.
3.2 Serial Number
This option is used to see the electronic serial number which should match the Columbus Instruments serial
tag on the outside of the cabinet. For service, this number may be referenced to lookup any specific details or
notes about your specific Treadmill and Controller. This option is non-editable.