Columbus JACK/Regent
2222 S. Third St., Columbus, Ohio 43207-2402 USA
MODEL 179D1100-56
50 TON ALLIGATOR AXLE JACK
PAGE -3-
8.0 Oil
Level
Proper oil level for most efficient operation is 1/2 inch below the filler hole when rams are completely
collapsed. The following hydraulic oils are recommended for use in ColumbusJACK/Regent jacks:
Exxon/Mobil Aero HF (MIL-5606)
Shell Tellus 10, 15
Exxon/Mobil DTE-11, -15
Shell Aerofluid 31 (MIL-PRF-83282)
Phillips 66 X/C 5606
Shell Aerofluid 41 (MIL-PRF-5606)
Royco 783 (Anderol) (MIL-PRF-6083)
Texaco Regal Oil R & O
(32, 46, 68, 100, 150, 220, 320, 460)
9.0
How to Locate and Remedy Trouble
If operational troubles are encountered, refer to the Trouble Shooting Chart which lists the most commonly
occurring problems and gives information which will facilitate lcoation of trouble source and determination
of remedial action.