DAILY MAINTENANCE
CLEANING THE SOLUTION TANK AND FILTER
With the solution tank empty:
1. turn on the tap
2. unscrew and carefully rinse the filter
3. remove the plug from the solution tank refill opening
4. rinse the inside of the tank with a jet of water
5. remove and clean the filter cartridge
6. reassemble everything, repeating the above-mentioned operations in the reverse
order
DISASSEMBLING AND CLEANING THE CYLINDRICAL BRUSHES
1. Connect the battery connector if it is not already connected
2. Turn the key to position "1"
3. Use the manipulator to lift the base (if it is not already raised)
4. Turn the key to the 0 position and remove it from the panel (carrying out the brush
disassembly operation with the power supply connected may cause injuries to the
hands).
ATTENTION!
This operation
must be carried out using gloves
to protect against contact with dangerous materials and
solutions.
3
1
2
4
5. With the base up, release the clip (6) and unthread the lower pin (7)
6. Raise the splash guard support (5) until the fixing screw (8) is in line with the
respective hole.
7. Remove the splash guard support (5), resting it on the floor.
8. Push the brush support plate (9) downwards, then pull it outward until it is released
from the brush.
9. Release the cylindrical brush (10) by pulling it towards you then removing it from
the tunnel
10. Clean the bristles of the brush with a jet of water
11.
Reassemble the cylindrical brushes (see ASSEMBLING THE CYLINDRICAL
BRUSHES)
CLEANING THE DRAWER
1. Remove the left-hand side splash guard
2. Unthread the hopper (1)
3. Empty the drawer and clean it with a jet of water
4. Reassemble the hopper
5. Reassemble the left-hand side splash guard
6
7
8
9
10
1
5